The aim of this paper is to compare two different methods for the calculation of the ultrasonic output power of underwater transducers: the radiation force balance, which is the standard method, and the laser heterodyne interferometry, which is rather used to depict displacement or velocity distributions of the acoustic field. Here it is shown that the latter can also be used to calculate the acoustic time-average power with an uncertainty of about 22%, the radiation force balance giving an uncertainty of 12% (with 95% confidence). The interferometry experiments performed with two transducers working at 2.25 MHz and 8.25 MHz showed that they produce different acoustic fields (respectively Gaussian and Lorentz-sigmoidal distributions). Taking into account the acoustic field profiles, the acoustic time-average power from interferometry was calculated. It was found very similar to the time-average power measured with the radiation force balance in the plane-wave assumption. (c) 2005 Elsevier B.V. All rights reserved.
机译:本文的目的是比较两种用于计算水下换能器超声输出功率的方法:辐射力平衡(这是标准方法)和激光外差干涉测量法(用于描述位移或速度分布)声场在此表明,后者还可以用于计算声时平均功率,不确定度约为22%,辐射力平衡给出的不确定度为12%(置信度为95%)。用两个工作在2.25 MHz和8.25 MHz的换能器进行的干涉测量实验表明,它们产生不同的声场(分别是高斯和洛伦兹S型分布)。考虑到声场分布,计算了干涉法的声时平均功率。发现与在平面波假设中利用辐射力平衡测得的时间平均功率非常相似。 (c)2005 Elsevier B.V.保留所有权利。