...
首页> 外文期刊>Ultrasound in Medicine and Biology >Measurement of depth-dependence and anisotropy of ultrasound speed of bovine articular cartilage in vitro.
【24h】

Measurement of depth-dependence and anisotropy of ultrasound speed of bovine articular cartilage in vitro.

机译:牛关节软骨的深度依赖性和超声速度各向异性的体外测量。

获取原文
获取原文并翻译 | 示例

摘要

The inhomogeneous and anisotropic mechanical properties and structural components of articular cartilage (artC) may cause complex acoustic properties in this important tissue. In this study, we used 50-MHz ultrasound (US) to measure in vitro the depth-dependence and anisotropy of the US speed of artC collected from the bovine patellae. The US speeds of 18 disk artC specimens sampled from 18 different patellae were measured in two orthogonal directions. One full-thickness layer (n=18) and three horizontal slices (n=18 x 3) with approximately equal thickness were prepared from each artC disk and measured with the US beam perpendicular to the artC surface. One full-thickness vertical slice (n=10) was measured at different depths with the US beam parallel to the artC surface. The measured US speeds of artC in the two orthogonal directions were significantly different (p < 0.001). The US speeds also significantly increased with the increase of tissue depth for both measurement directions (p < 0.001). The USspeeds of artC from the superficial to deep regions were 1518 +/- 17 (mean + SD), 1532 +/- 26 and 1554 +/- 42 m/s for the US beam parallel to the artC surface, and 1574 +/- 29, 1621 +/- 34 and 1701 +/- 36 m/s for the beam perpendicular to the artC surface. The sound speed of the full-thickness layer was 1636 +/- 25 m/s. The results suggested that the depth-dependence and anisotropy of the US speed in artC should be taken into account when US is used for the artC measurement. It was also demonstrated in this study, using additional specimens (5 x 2), that the swelling of artC after detaching from its subchondral bone could cause the change of its sound speed.
机译:关节软骨(artC)的不均匀和各向异性的机械性能和结构组件可能会在此重要组织中引起复杂的声学特性。在这项研究中,我们使用50 MHz超声波(US)体外测量了从牛骨收集的artC的US速度的深度依赖性和各向异性。在两个正交方向上测量了从18个不同骨采样的18个artC标本的US速度。从每个artC磁盘准备一个全厚度层(n = 18)和三个水平切片(n = 18 x 3),其厚度大致相等,并使用垂直于artC表面的US光束进行测量。在US光束与artC表面平行的情况下,在不同深度测量了一个全厚度的垂直切片(n = 10)。在两个正交方向上测得的artC美国速度明显不同(p <0.001)。在两个测量方向上,US速度也随着组织深度的增加而显着增加(p <0.001)。 artC从浅到深区域的美国速度分别为1518 +/- 17(平均+ SD),平行于artC表面的US光束的1532 +/- 26和1554 +/- 42 m / s,以及1574 + / -垂直于artC表面的光束为29、1621 +/- 34和1701 +/- 36 m / s。全厚度层的声速为1636 +/- 25 m / s。结果表明,当使用USC进行artC测量时,应考虑artC中US速度的深度依赖性和各向异性。在这项研究中还证明了,使用其他标本(5 x 2),artC从软骨下骨分离后的肿胀可能会导致其音速变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号