首页> 外文期刊>Quality Assurance: Good Practice, Regulation, and Law >LESSONS LEARNED IN PREPARING METHOD 29 FILTERS FOR COMPLIANCE TESTING AUDITS
【24h】

LESSONS LEARNED IN PREPARING METHOD 29 FILTERS FOR COMPLIANCE TESTING AUDITS

机译:制备方法29过滤器中的经验教训

获取原文
获取原文并翻译 | 示例
           

摘要

Companies conducting compliance testing are required to analyze audit samples at the time they collect and analyze the stack samples if audit samples are available.Eastern Research Group (ERG) provides technical support to the EPA's Emission Measurements Center's Stationary Source Audit Program (SSAP) for developing,preparing,and distributing performance evaluation samples and audit materials.These audit samples are requested via the regulatory Agency and include spiked audit materials for EPA Method 29-Metals Emissions from Stationary Sources,as well as other methods.To provide appropriate audit materials to federal,state,tribal,and local governments,as well as agencies performing environmental activities and conducting emission compliance tests,ERG has recently performed testing of blank filter materials and preparation of spiked filters for EPA Method 29.For sampling stationary sources using an EPA Method 29 sampling train,the use of filters without organic binders containing less than 1.3 #mu#g/in.~2 of each of the metals to be measured is required.Risk Assessment testing imposes even stricter requirements for clean filter background levels.Three vendor sources of quartz fiber filters were evaluated for background contamination to ensure that audit samples would be prepared using filters with the lowest metal background levels.A procedure was developed to test new filters,and a cleaning procedure was evaluated to see if a greater level of cleanliness could be achieved using an acid rinse with new filters.Background levels for filters supplied by different vendors and within lots of filters from the same vendor showed a wide variation,confirmed through contact with several analytical laboratories that frequently perform EPA Method 29 analyses.It has been necessary to repeat more than one compliance test because of suspect metals background contamination levels.An acid cleaning step produced improvement in contamination level,but the difference was not significant for most of the Method 29 target metals.As a result of our studies,we conclude:centre dot Filters for Method 29 testing should be purchased in lots as large as possible.centre dot Testing firms should pre-screen new boxes and/or new lots of filters used for Method 29 testing.centre dot Random analysis of three filters (top,middle,bottom of the box) from a new box of vendor filters before allowing them to be used in field tests is a prudent approach.centre dot A box of filters from a given vendor should be screened,and filters from this screened box should be used both for testing and as field blanks in each test scenario to provide the level of quality assurance required for stationary source testing.
机译:进行合规性测试的公司必须在收集审计样本时分析审计样本,如果有审计样本可用,则应进行分析。美国东部研究小组(ERG)为EPA排放测量中心的固定污染源审计计划(SSAP)提供技术支持,准备和分发绩效评估样品和审核材料。这些审核样品是通过监管机构索取的,其中包括针对EPA方法29-固定来源的金属排放以及其他方法的加标审核材料。向联邦政府提供适当的审核材料,州,部落和地方政府,以及进行环境活动和进行排放合规性测试的机构,ERG最近针对EPA方法29进行了空白滤料的测试和加标滤嘴的制备。对于使用EPA方法29的固定源采样采样序列,使用不含有机粘结剂的过滤器每种被测金属的含量必须达到1.3#mu#g / in。〜2。风险评估测试对清洁的过滤器背景水平提出了更严格的要求。对三个供应商的石英纤维过滤器进行了背景污染评估,以确保将使用金属背景水平最低的过滤器制备审核样品。开发了测试新过滤器的程序,并对清洁程序进行了评估,以查看使用新过滤器进行酸洗是否可以达到更高的清洁度。由不同供应商提供的过滤器以及同一供应商提供的许多过滤器中的过滤器显示出很大的差异,这是通过与经常执行EPA方法29分析的几个分析实验室联系而确认的。由于金属可疑,有必要重复一次以上的一致性测试本底污染水平。酸清洗步骤可提高污染水平,但差异不明显根据我们的研究结果,我们得出以下结论:应尽可能多地购买用于方法29测试的中心点过滤器。中心点测试公司应预先筛选新的盒子和/或新的谨慎的方法是在方法29的测试中使用许多过滤器。中心点从新包装的供应商过滤器盒中随机分析三个过滤器(顶部,中间,底部)是一种审慎的方法。应筛选来自给定供应商的过滤器框,并应将此筛选框中的过滤器用于测试,并在每个测试方案中用作字段空白,以提供固定源测试所需的质量保证水平。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号