...
首页> 外文期刊>Proteomics >Increased quantitative proteome coverage with C-13/C-12-based, acid-cleavable isotope-coded affinity tag reagent and modified data acquisition scheme
【24h】

Increased quantitative proteome coverage with C-13/C-12-based, acid-cleavable isotope-coded affinity tag reagent and modified data acquisition scheme

机译:使用基于C-13 / C-12,酸可裂解的同位素编码的亲和标签试剂和改良的数据采集方案,提高了定量蛋白质组学的覆盖率

获取原文
获取原文并翻译 | 示例

摘要

Quantitative protein profiling using the isotope-coded affinity tag (ICAT((TM))) Method and tandem mass spectrometry (MS) enables the pair-wise comparison of protein expression levels in biological samples. A new version of the ICAT reagent with an acid-cleavable bond, which allows removal of the biotin moiety prior to MS and which utilizes C-13 substitution for C-12 in the heavy- ICAT reagent rather than H-2 (for H-1) as in the original reagent (Gygi, S. P., Rist, B., Gerber, S. A., Frantisek, T. Gelb, M. H., Aebersold, R., Quantitative analysis of complex protein mixtures using isotope-coded affinity tags. Nat. Biotechnol. 1999, 17, 994-999), was investigated. We developed and validated an MS data acquisition strategy using this new reagent that results in an increased number of protein identifications per experiment, without losing the accuracy of protein quantification. This was achieved by following a single survey (precursor) ion scan and serial collision induced dissociations (CIDs) of four different precursor ions observed in the prior survey scan. This strategy is common to many high-performance liquid chromatography-electro spray ionization (HPLC-ESI)-MS shotgun proteomic strategies, but heretofore not to ICAT experiments. This advance is possible because the new ICAT reagent uses C-13 as the "heavy" element rather than H-2, thus, eliminating the slight delay in retention time of ICAT-Iabeled "light" peptides on a C18-based HPLC separation that occurs with 2 H and 1H. Analyses using this new scheme of an ICAT-labeled trypsin -digested six protein mixture as well as a tryptic digest of a total yeast lysate, indicated that about two times more proteins were identified in a single analysis, and that there was no loss in accuracy of quantification.
机译:使用同位素编码的亲和标签(ICAT(TM))方法和串联质谱(MS)进行定量蛋白质谱分析,可以成对比较生物样品中蛋白质的表达水平。具有酸可裂解键的ICAT试剂的新版本,它允许在MS之前去除生物素部分,并利用C-13取代重ICAT试剂中的C-12而不是H-2(对于H- 1)如原始试剂(Gygi,SP,Rist,B.,Gerber,SA,Frantisek,T. Gelb,MH,Aebersold,R.)中所述,使用同位素编码的亲和标记物对复杂的蛋白质混合物进行定量分析。 (1999,17,994-999)进行了调查。我们使用这种新试剂开发并验证了MS数据采集策略,该策略可增加每个实验中蛋白质鉴定的数量,而又不会损失蛋白质定量的准确性。这是通过对单次调查(前体)离子扫描和在先前的调查扫描中观察到的四个不同前体离子进行系列碰撞诱导解离(CID)来实现的。此策略是许多高性能液相色谱-电喷雾电离(HPLC-ESI)-MS gun弹枪蛋白质组学策略所共有的,但迄今为止,这对ICAT实验而言并非如此。这种进步是可能的,因为新的ICAT试剂使用C-13作为“重”元素而不是H-2,从而消除了在基于C18的HPLC分离中ICAT标记的“轻”肽的保留时间的轻微延迟。在2 H和1H下发生。使用这种新方案对ICAT标记的胰蛋白酶消化的六种蛋白质混合物以及整个酵母裂解物的胰蛋白酶消化液进行分析,结果表明,一次分析中鉴定出的蛋白质大约多出两倍,并且准确性没有损失量化。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号