Alcohol selectivity and measurement of ethanol concentrations in liquors using Teflon (R) AF2400-coated gold-deposited surface plasmon resonance-based glass rod sensor

机译:酒精选择性和使用涂有特氟龙(AF)2400的金沉积的表面等离子体激元共振的玻璃棒传感器测量酒中乙醇的浓度

获取原文
获取原文并翻译 | 示例
       

摘要

A gold (Au)-deposited surface plasmon resonance (SPR)-based glass rod sensor coated with an alpha-mercaptoethyl-omega-methoxy polyoxyethylene (PEG thiol) layer and a Teflon AF2400 overlayer with high selectivity for small molecules contained in aqueous solutions was developed. The PEG thiol layer forms a space (approximately 13 nm wide) for the analytes to accumulate between the Au film (45 nm thick) and the Teflon layer (approximately 12 mu m thick). The water and alcohol content in the sample solutions pass selectively through the porous Teflon overlayer, accumulate in the PEG thiol spacer layer and are then detected through the SPR phenomenon. Cross-sectional scanning electron microscope imaging of the sensor was used to measure the thickness of the Teflon overlayer on the Au film. The sensor selectivity was then evaluated using aqueous solutions of various alcohols. The sensor responds reversibly to the concentrations of only monohydric alcohols. The response is faster than that of the Teflon AF1600-coated sensor as a result of the increased permeability and the reduced thickness of the Teflon AF2400 overlayer. The sensor maintains both its sensitivity and its selectivity for as long as 6 months. Direct measurement of the ethanol concentrations of aqueous ethanol solutions that were mixed with interference compounds is possible using this sensor. The ethanol concentrations of various liquors were measured directly. This sensor is a unique device with functions for both separation and detection of the analytes. (C) 2015 Elsevier B.V. All rights reserved.
机译:基于金(Au)沉积的表面等离振子共振(SPR)的玻璃棒传感器涂有α-巯基乙基-ω-甲氧基聚氧乙烯(PEG硫醇)层和对水溶液中的小分子具有高选择性的Teflon AF2400覆盖层发达。 PEG硫醇层形成一个空间(约13 nm宽),使分析物积聚在Au膜(45 nm厚)和Teflon层(约12μm厚)之间。样品溶液中的水和酒精含量选择性地穿过多孔的Teflon覆盖层,积聚在PEG硫醇间隔层中,然后通过SPR现象进行检测。传感器的截面扫描电子显微镜成像用于测量Au膜上的Teflon覆盖层的厚度。然后使用各种醇的水溶液评估传感器的选择性。传感器仅对一元醇的浓度做出可逆的响应。由于铁氟龙AF2400覆盖层的磁导率提高和厚度减小,其响应速度比特氟隆AF1600涂层传感器快。传感器可同时保持其灵敏度和选择性长达6个月。使用此传感器可以直接测量与干扰化合物混合的乙醇水溶液的乙醇浓度。直接测量各种液体的乙醇浓度。该传感器是独特的设备,具有分离和检测分析物的功能。 (C)2015 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号