首页> 外文期刊>Progress in Organic Coatings: An International Review Journal >The effects of zinc ions on the performance of epoxy coated mild steel under cathodic protection (CP)
【24h】

The effects of zinc ions on the performance of epoxy coated mild steel under cathodic protection (CP)

机译:锌离子对阴极保护(CP)环氧涂层低碳钢性能的影响

获取原文
获取原文并翻译 | 示例
           

摘要

This work aimed to address the issues that arise when cathodic protection is applied to a coated structure. The use of zinc chloride (ZnCl_2) as a corrosion inhibitor was suggested; the idea was to bridge the weakly cross linked areas on the coating by depositing a film of zinc compounds in order to seal them from the corrosive environment. It was shown that the addition of 300 ppm ZnCl_2 to 0.6 M KCl has an impact on the performance of the coating under the two different levels of potential that were used (-0.78 V and -1.1 V SCE) by maintaining the resistance of the coating above the border line between fair and poor coating for a period of 35 days; this was attributed to the deposition of zinc oxide (ZnO) at the base of the weakly cross linked areas. EDAX examination has confirmed the presence of zinc ions on the metal surface after immersion; this result was supported by the detection of ZnO using XRD technique.
机译:这项工作旨在解决将阴极保护应用于涂层结构时出现的问题。建议使用氯化锌(ZnCl_2)作为缓蚀剂。其想法是通过沉积一层锌化合物膜来桥接涂层上的弱交联区域,以将其与腐蚀环境隔离。结果表明,将300 ppm ZnCl_2添加到0.6 M KCl中会通过保持涂层的电阻而在所使用的两种不同电位水平下(-0.78 V和-1.1 V SCE)对涂层的性能产生影响。在白涂和不良涂膜之间的边界线上方,持续35天;这归因于在弱交联区域的底部沉积了氧化锌(ZnO)。 EDAX检查已证实浸没后金属表面上存在锌离子。使用XRD技术检测ZnO可以支持该结果。