Hexapod machine tool (HMT) is a device designed for micro milling; however, the deviations of the HMT's kinematic parameters due to manufacture and assembly errors can definitely affect its running accuracy. To identify the real kinematic parameters so as to improve the running accuracy of the HMT, a novel calibration test was performed on a bridge-type coordinate measuring machine. In the present research, a mathematical model was derived to present the relationship between pose errors and the errors of kinematic parameters of the HMT, the measurement method based on coordinate measuring machine was designed and a calibration experiment was carried out subsequently. The experimental results reveal that after calibration, both the position errors and orientation errors of the HMT decreased significantly, the symmetrical errors were improved as well. In addition, it is found that the running accuracy of the HMT is running direction dependent, which depends on the HTM's structures. The present research provides researchers with a new and effective calibration method to improve the running accuracy of HMTs.
机译:六足机床(HMT)是专为微铣削而设计的设备;但是,由于制造和装配错误导致的HMT运动学参数的偏差必定会影响其运行精度。为了识别实际的运动学参数,以提高HMT的运行精度,在桥式坐标测量机上进行了新颖的校准测试。本研究建立了一个数学模型来表示姿态误差与HMT运动学参数误差之间的关系,设计了基于坐标测量机的测量方法,并进行了校准实验。实验结果表明,校准后,HMT的位置误差和方向误差均显着降低,对称误差也得到改善。此外,发现HMT的运行精度取决于运行方向,这取决于HTM的结构。本研究为研究人员提供了一种新的有效的校准方法,以提高HMT的运行精度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号