...
首页> 外文期刊>Prehospital emergency care >Regional blood flow after pneumatic anti-shock garment inflation.
【24h】

Regional blood flow after pneumatic anti-shock garment inflation.

机译:气动抗冲击衣服充气后局部血流。

获取原文
获取原文并翻译 | 示例

摘要

OBJECTIVE: To determine whether fully inflated pneumatic anti-shock garments (PASGs) decrease blood flow to abdominal and retroperitoneal organs. METHODS: An experimental study was conducted using a convenience sample of ten healthy adults. A duplex Doppler ultrasound was used to image and measure blood flow at the aortic root (cardiac output), left carotid artery, left subclavian artery, superior mesenteric artery (SMA), left renal artery, and distal aorta. Each subject was imaged before and after inflation of all three compartments of the garment to 90 mm Hg. Data were analyzed with paired t-tests. RESULTS: PASG inflation did not affect cardiac output (5.45 vs. 5.83 L/min, 95% confidence limit (CL) for mean -0.97 to 0.30, p = 0.26), left carotid artery flow (0.34 vs. 0.35 L/min, 95% CL for mean -0.06 to 0.04, p = 0.70), or left subclavian artery flow (0.12 vs. 0.11 L/min, 95% CL for mean -0.01 to 0.03, p = 0.47). Inflation did cause the aortic flow immediately distal to the renal artery to decrease markedly in all subjects (1.01 vs. 0.11 L/min, 95% CL for mean 0.79 to 1.19, p < 0.001). Flow immediately above this point appeared unaffected. Physical interference with the ultrasound probe by the garment precluded measurement of SMA or renal artery flow in five subjects. In the remaining subjects, these values did not change significantly (SMA 0.40 vs. 0.28 L/min, 95% CL for mean -0.11 to 0.33, p = 0.23; renal artery 0.44 vs. 0.51 L/min, 95% CL for mean -0.09 to 0.08, p = 0.78). CONCLUSION: PASG inflation caused a dramatic decrease in aortic blood flow over a small area immediately distal to the renal arteries but had little or no effect above this point. This provides support for the use of PASG to decrease otherwise uncontrollable hemorrhage from the iliac, pelvic, and leg vessels, but not for injuries above them.
机译:目的:确定完全充气的气动抗冲击衣服(PASG)是否能减少流向腹部和腹膜后器官的血液。方法:使用十名健康成年人的便利样本进行了一项实验研究。双工多普勒超声用于成像和测量主动脉根(心脏输出),左颈动脉,左锁骨下动脉,肠系膜上动脉(SMA),左肾动脉和远端主动脉的血流。在将服装的所有三个隔室充气至90 mm Hg之前和之后对每个对象进行成像。用配对t检验分析数据。结果:PASG充气未影响心输出量(5.45比5.83 L / min,95%置信限(CL),平均-0.97至0.30,p = 0.26),左颈动脉血流(0.34 vs. 0.35 L / min, 95%CL的平均值为-0.06至0.04,p = 0.70)或左锁骨下动脉血流(0.12 vs.0.11 L / min,95%CL的平均值为-0.01至0.03,p = 0.47)。在所有受试者中,通货膨胀确实导致紧接肾动脉远端的主动脉流量明显减少(1.01比0.11 L / min,95%CL,平均0.79至1.19,p <0.001)。高于此点的流量似乎不受影响。服装对超声探头的物理干扰使得无法测量五个对象的SMA或肾动脉流量。在其余受试者中,这些值没有显着变化(SMA 0.40 vs. 0.28 L / min,平均-0.11至0.33,95%CL,p = 0.23;肾动脉0.44 vs. 0.51 L / min,平均95%CL -0.09至0.08,p = 0.78)。结论:PASG充气导致紧接肾动脉远端的小区域主动脉血流量显着减少,但在此点以上几乎没有影响。这为使用PASG减少否则无法控制的the,骨盆和腿部血管出血提供了支持,但不适用于其上方的损伤。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号