首页> 外文期刊>Polymer Composites >Experimental Failure Analysis of Bolted Joints in Moisture- and Temperature-Induced Composite Laminates under Preload
【24h】

Experimental Failure Analysis of Bolted Joints in Moisture- and Temperature-Induced Composite Laminates under Preload

机译:湿热复合材料层合板预应力螺栓连接的试验失效分析

获取原文
获取原文并翻译 | 示例

摘要

In this study, an experimental investigation was carried out in a bolted glass fiber-reinforced laminate under preload moments. The stacking sequence at the composite laminate was chosen as [90°/0°/45°/-30°]_s. The preload moments were selected as 2, 4, and 6 Nm, in order to compare the influence of preload moments on failure modes and strengths. Some specimens were subjected to hot pure water at 70°C for 7 days. The bearing strength in this case was measured again under the same preload moments of 2, 4, and 6 Nm. It is found that the bearing strength of the specimen waited in hot water was 5.4% smaller than that of the specimen in dry condition.
机译:在这项研究中,在预紧力作用下,对螺栓连接的玻璃纤维增​​强层压板进行了实验研究。复合层压板的堆叠顺序选择为[90°/ 0°/ 45°/ -30°] _s。为了比较预紧力矩对破坏模式和强度的影响,预紧力矩选择为2、4和6 Nm。一些样品在70°C的纯净水中浸泡7天。在这种情况下,在相同的2、4和6 Nm的预紧力矩下再次测量轴承强度。发现在热水中等待的样本的承载强度比在干燥条件下的样本的承载强度小5.4%。