首页> 外文期刊>Plasma Science & Technology >Calculation of Response Function for Bonner Sphere Spectrometer Based on Geant4
【24h】

Calculation of Response Function for Bonner Sphere Spectrometer Based on Geant4

机译:基于Geant4的Bonner球谱仪响应函数的计算。

获取原文
获取原文并翻译 | 示例
       

摘要

In order to make further studies on fusion neutron diagnosis on HL-2A /HL-2M, we have developed and succeeded in the calculation of the Response Function for a Bonner sphere spectrometer, which consists of eight polyethylene spheres with He-3 proportional counters inside. The response function of the Bonner spectrometer to neutrons is of fundamental importance for its neutron spectrum unfolding procedure and is directly related to the quality of the unfolded spectrum. In this paper, we calculated the response function to neutrons from 10(-9) MeV to 100 MeV by Geant4. In order to test the accuracy of the Geant4 simulation, we apply it to measure an Am-241-Be neutron source, and the measured neutron counts of the spectrometer and simulated counts are found to be highly consistent, with a relative error up to 9.3%. This has proven the calculation of the neutron response of the Bonner sphere spectrometer by Geant4 to be quite accurate.
机译:为了进一步研究聚变中子对HL-2A / HL-2M的诊断,我们开发并成功计算了Bonner球谱仪的响应函数,该谱仪由八个带有He-3比例计数器的聚乙烯球组成。邦纳光谱仪对中子的响应功能对其中子光谱展开过程至关重要,并且直接关系到展开光谱的质量。在本文中,我们通过Geant4计算了从10(-9)MeV到100 MeV对中子的响应函数。为了测试Geant4模拟的准确性,我们将其用于测量Am-241-Be中子源,发现光谱仪的中子计数与模拟计数高度一致,相对误差最高为9.3 %。这证明了Geant4对Bonner球谱仪的中子响应的计算是相当准确的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号