JT-60SA is a fully superconducting coil tokamak upgraded from the JT-60U. This paper focused on the integrity of the top lid of cryostat in JT-60SA. The design requirement for the cryostat in normal operations is to achieve vacuum insulation of 10~(-3) Pa, and the top flange of the top lid is lightly welded onto its body flange. The weld is tensile-loaded by bending deformation of the top lid due to vacuum pressure of external 0.1 MPa. This weld integrity is evaluated with tensile-load reduction, which results in clamp reinforcement. The structural integrity of the top lid is validated.
机译:JT-60SA是从JT-60U升级而来的完全超导线圈托卡马克。本文重点介绍JT-60SA中低温恒温器顶盖的完整性。低温恒温器在正常操作中的设计要求是实现10〜(-3)Pa的真空绝缘,并且将顶盖的顶部法兰轻轻焊接到其本体法兰上。由于外部0.1 MPa的真空压力,顶盖弯曲变形,从而使焊缝承受拉伸载荷。可以通过降低拉伸载荷来评估这种焊接完整性,从而可以提高夹紧力。顶盖的结构完整性得到验证。