首页> 外文期刊>Water Research >Accurate and self-consistent procedure for determining pH in seawater desalination brines and its manifestation in reverse osmosis modeling
【24h】

Accurate and self-consistent procedure for determining pH in seawater desalination brines and its manifestation in reverse osmosis modeling

机译:准确,自洽的海水淡化盐水pH值测定方法及其在反渗透模型中的体现

获取原文
获取原文并翻译 | 示例
           

摘要

Measuring and modeling pH in concentrated aqueous solutions in an accurate and consistent manner is of paramount importance to many R&D and industrial applications, including RO desalination. Nevertheless, unified definitions and standard procedures have yet to be developed for solutions with ionic strength higher than ~0.7 M, while implementation of conventional pH determination approaches may lead to significant errors. In this work a systematic yet simple methodology for measuring pH in concentrated solutions (dominated by Na~+/ Cl~-) was developed and evaluated, with the aim of achieving consistency with the Pitzer ion-interaction approach. Results indicate that the addition of 0.75 M of NaCl to NIST buffers, followed by assigning a new standard pH (calculated based on the Pitzer approach), enabled reducing measured errors to below 0.03 pH units in seawater RO brines (ionic strength up to 2 M). To facilitate its use, the method was developed to be both conceptually and practically analogous to the conventional pH measurement procedure. The method was used to measure the pH of seawater RO retentates obtained at varying recovery ratios. The results matched better the pH values predicted by an accurate RO transport model. Calibrating the model by the measured pH values enabled better boron transport prediction. A Donnan-induced phenomenon, affecting pH in both retentate and permeate streams, was identified and quantified.
机译:以精确且一致的方式测量和建模浓水溶液中的pH值对于许多研发和工业应用(包括反渗透脱盐)至关重要。然而,对于离子强度高于〜0.7 M的溶液,尚未制定统一的定义和标准程序,而实施常规pH测定方法可能会导致重大错误。在这项工作中,开发并评估了一种用于测量浓溶液(以Na〜+ / Cl〜-为主)中的pH值的系统而简单的方法,目的是与Pitzer离子相互作用方法保持一致。结果表明,向NIST缓冲液中添加0.75 M NaCl,然后分配新的标准pH(基于Pitzer方法计算),可以将海水RO盐水中的测量误差降低至0.03 pH单位以下(离子强度最高2 M )。为了便于使用,该方法在理论上和实践上都与常规pH测量程序类似。该方法用于测量在不同回收率下获得的海水RO截留液的pH值。结果与准确的反渗透传​​输模型预测的pH值更好地匹配。通过测量的pH值对模型进行校准,可以更好地预测硼的运移。识别并定量了由Donnan引起的现象,该现象会影响渗余液和渗透液的pH值。

著录项

  • 来源
    《Water Research》 |2014年第1期|187-195|共9页
  • 作者

    Oded Nir; Esra Marvin; Ori Lahav;

  • 作者单位

    Faculty of Civil and Environmental Engineering, Technion - IIT, Haifa 32000, Israel;

    Faculty of Environmental Engineering, Helsinki Metropolia University of Applied Sciences, Finland;

    Faculty of Civil and Environmental Engineering, Technion - IIT, Haifa 32000, Israel;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    pH; Brine; Pitzer; Phreeqc; Reverse-osmosis;