Household on-site septic systems with secondary waste-water treatment in Anchorage, Alaska, were sampled and analyzed for performance parameters during the winter to spring months. System types included intermittent dosing sand filters (ISF), three types of recirculating trickling filters (RTF), and suspended-growth aeration tanks. Total nitrogen from the trickling filter and aeration tank effluent was fairly uniform, at approximately 30 mg/L. Total suspended solids (TSS) means were mostly less than 15 mg/L. The 5-day biochemical oxygen demand (BOD_5) showed considerable variability, with means ranging from 9.2 mg/ L for ISFs up to 39.5 mg/L for one type of RTF, even though this type has shown excellent results in several test programs. The data suggested that effluent temperature within the sample range had almost no effect on effluent concentrations of BOD_5 or TSS and only a small effect on the removal of total nitrogen. Non-climatic factors were probably of equal importance to treatment results.
机译:在阿拉斯加的安克雷奇市,对家庭现场化粪池系统进行了二次废水处理,并对冬季至春季的性能参数进行了采样和分析。系统类型包括间歇式定量沙滤器(ISF),三种类型的循环滴滤器(RTF)和悬浮式曝气池。从滴滤池和曝气池流出的总氮相当均匀,约为30 mg / L。总悬浮固体(TSS)平均值大多低于15 mg / L。 5天生化需氧量(BOD_5)表现出很大的可变性,均值范围从ISF的9.2 mg / L到一种RTF的39.5 mg / L不等,即使该类型在多个测试程序中均显示了出色的结果。数据表明,样品温度范围内的出水温度对BOD_5或TSS的出水浓度几乎没有影响,而对总氮的去除影响很小。非气候因素可能对治疗结果同样重要。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号