Computational fluid dynamics (CFD) was used to simulate the mixing characteristics of a small circular anaerobic digester tank (diameter 6 m) equipped sequentially with 13 different plunger type vertical linear motion mixers and two different type internal draft-tube mixers. Rates of mixing of step injection of tracers were calculated from which active volume (AV) and hydraulic retention time (HRT) could be calculated. Washout characteristics were compared to analytic formulae to estimate any presence of partial mixing, dead volume, short-circuiting, or piston flow. Active volumes were also estimated based on tank regions that exceeded minimum velocity criteria. The mixers were ranked based on an ad hoc criteria related to the ratio of AV to unit power (UP) or AV/ UP. The best plunger mixers were found to behave about the same as the conventional draft-tube mixers of similar UP.
机译:计算流体动力学(CFD)用于模拟依次装有13种不同的柱塞型立式直线运动混合器和两种不同类型的内部引流管混合器的小型圆形厌氧消化池(直径6 m)的混合特性。计算示踪剂的逐步注入混合速率,由此可计算出活性体积(AV)和水力停留时间(HRT)。将冲洗特性与分析公式进行比较,以估计是否存在部分混合,死体积,短路或活塞流。还根据超出最小速度标准的储罐区域估算了活动体积。根据与AV与单位功率(UP)或AV / UP的比率相关的临时标准对混频器进行排名。发现最好的柱塞式混合器的性能与具有类似UP的传统引流管混合器大致相同。