In a few cases, atmospheric particulate matter characterization was taken into account together with aerobiological monitoring but never in an archive. The aim of this study was to estimate the air quality, by means of both chemical-physical and microbiological studies, at the Ca' Granda Historical Archive (Milan, Italy) that houses an important collection of documents from the 12th century. Temperature and relative humidity were measured in the rooms. Particulate matter (PM2.5) concentrations were quantified and the chemical composition, in terms of ionic components, elements, and carbonaceous fraction (total, organic, and elemental carbon) determined. The gaseous pollutants NO_2, SO_2, and O_3 and indoor acidity were also measured. Aerobiological monitoring (aerobic heterotrophic bacteria and fungi) was performed as volumes stored in the Archive were composed of organic materials, a potential energy and carbon source. In this paper, we present our findings and propose some guidelines for a better preservation of the documents.
机译:在少数情况下,将大气颗粒物的表征与航空生物监测一起考虑在内,但从未在档案中进行。这项研究的目的是通过化学,物理和微生物学研究来评估卡格兰达历史档案馆(意大利米兰)的空气质量,该档案馆藏有12世纪的重要文献资料。在房间中测量温度和相对湿度。量化颗粒物(PM2.5)的浓度,并根据离子成分,元素和碳含量(总碳,有机碳和元素碳)确定化学成分。还测量了气态污染物NO_2,SO_2和O_3以及室内酸度。进行空气生物学监测(需氧异养细菌和真菌),因为档案库中存储的体积由有机材料,势能和碳源组成。在本文中,我们介绍了我们的发现并提出了一些指南,以更好地保存文档。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号