A considerable amount of parametric data was generated to aid in the design of concrete mausoleums for storing old SGs. These data include both skyshine and direct gamma dose rate estimates as a function of ten mausoleum and SG variables. Together with a specially developed application methodology, the parametric data can be used to estimate wall and roof thicknesses for new mausoleums having external dose rate requirements. This work should help the facility design engineer to better estimate actual wall and roof thicknesses needed to protect plant personnel and the public from the radiological hazard posed by old SGs, and at the same time minimize construction costs for mausoleum shielding.
机译:生成了大量的参数数据,以帮助设计用于存储旧SG的混凝土陵墓。这些数据包括作为十个陵墓和SG变量的函数的天照和直接伽玛剂量率估计。结合专门开发的应用方法,该参数数据可用于估计具有外部剂量率要求的新陵墓的壁厚和屋顶厚度。这项工作应有助于设施设计工程师更好地估算实际的墙和屋顶厚度,以保护工厂人员和公众免受旧SG所造成的放射危害,同时最大程度地降低陵墓屏蔽的建设成本。