首页> 外文期刊>Transactions of the American nuclear society >Aerosol Filter Sample Inhomogeneity in Samples with Debris from the Fukushima Diiachi Nuclear Accident
【24h】

Aerosol Filter Sample Inhomogeneity in Samples with Debris from the Fukushima Diiachi Nuclear Accident

机译:福岛Diiachi核事故中带有碎片的样品中的气溶胶过滤器样品不均匀性

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Results showed that unaccounted uncertainty ranged from 2% to 10% for ~(137)Cs (6% average). The Cs results showed that unaccounted uncertainty ranged from 0.4% to 8.7% (5% average). These sample inhomogeneities are in the range to account for the differences noted between the RASA and HVAS data. The variance could be the result of aerosol sampler design creating non-uniform aerosol deposits or it could due to actual inhomogenieties in the air mass. Regardless, such differences should be noted within aerosol sampling results and taken into account when performing forensics calculations utilizing the data.
机译:结果表明,〜(137)Cs(平均6%)的不确定不确定性范围为2%至10%。 Cs结果显示,不确定的不确定性范围为0.4%至8.7%(平均5%)。这些样本不均匀性在考虑RASA和HVAS数据之间指出的差异的范围内。这种差异可能是由于气溶胶采样器设计产生了不均匀的气溶胶沉积所致,也可能是由于空气质量的实际不均匀性造成的。无论如何,这些差异应在气溶胶采样结果中记录下来,并在利用数据进行取证计算时予以考虑。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号