首页> 外文期刊>Thin-Walled Structures >Experimental study on axially preloaded circular steel tubes subjected to low-velocity transverse impact
【24h】

Experimental study on axially preloaded circular steel tubes subjected to low-velocity transverse impact

机译:轴向预应力圆形钢管低速横向冲击试验研究

获取原文
获取原文并翻译 | 示例
       

摘要

Steel circular hollow section tubes are widely used as tubular structural members, and impact accidents usually occur while these tubes are in their working states. This paper presents experimental studies on axially preloaded circular steel tubes subjected to transverse low-velocity mass impact. A total of 32 impact tests, representing four types of scenarios, are conducted to investigate the influences of preloading and the boundary condition on the structural responses of tubes. An axial force loading system is designed, and a bladder accumulator is adopted in the system to compensate for the axial compressive loading. The test processes of the tubes under transverse impact are described in detail, and four failure modes are identified. All specimens of the four scenario types deformed according to the three-hinge mechanism. Based on the test results, the influence and mechanism of axial force are proposed. The effects of axial tension, axial compression and the boundary condition on the structural behaviour of tubes are discussed. The results show that the axial tension can enhance the bending resistance and lateral collapse capacity of tubes, while the axial compression reduces the collapse capacity significantly. By comparing the responses of tubes under different boundary conditions, the lateral resistance of tubes and the structural response are shown to have a strong correlation with the axial constraint.
机译:圆形空心截面钢管被广泛用作管状结构构件,并且在这些钢管处于其工作状态时通常会发生碰撞事故。本文介绍了承受横向低速质量冲击的轴向预压圆形钢管的实验研究。总共进行了代表四种类型场景的32个冲击试验,以研究预紧力和边界条件对管结构响应的影响。设计了轴向力加载系统,并在系统中采用了气囊蓄能器来补偿轴向压缩载荷。详细描述了在横向冲击下管的测试过程,并确定了四种失效模式。四种场景类型的所有标本均根据三铰链机制变形。根据试验结果,提出了轴向力的影响及其机理。讨论了轴向张力,轴向压缩和边界条件对管材结构行为的影响。结果表明,轴向拉力可以提高管材的抗弯强度和侧向抗压能力,而轴向压缩则显着降低管的抗压能力。通过比较不同边界条件下管的响应,表明管的侧向阻力和结构响应与轴向约束有很强的相关性。

著录项

  • 来源
    《Thin-Walled Structures》 |2018年第9期|161-175|共15页
  • 作者单位

    Key Lab of Structures Dynamic Behaviour and Control of the Ministry of Education, Harbin Institute of Technology,Key Lab of Smart Prevention and Mitigation of Civil Engineering Disasters of the Ministry of Industry and Information Technology, Harbin Institute of Technology;

    Key Lab of Structures Dynamic Behaviour and Control of the Ministry of Education, Harbin Institute of Technology,Key Lab of Smart Prevention and Mitigation of Civil Engineering Disasters of the Ministry of Industry and Information Technology, Harbin Institute of Technology;

    Key Lab of Structures Dynamic Behaviour and Control of the Ministry of Education, Harbin Institute of Technology,Key Lab of Smart Prevention and Mitigation of Civil Engineering Disasters of the Ministry of Industry and Information Technology, Harbin Institute of Technology;

    Key Lab of Structures Dynamic Behaviour and Control of the Ministry of Education, Harbin Institute of Technology,Key Lab of Smart Prevention and Mitigation of Civil Engineering Disasters of the Ministry of Industry and Information Technology, Harbin Institute of Technology;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Circular steel tubes; Impact test; Axial force loading system; Preloadings; Boundary conditions;

    机译:圆形钢管;冲击试验;轴向力加载系统;预加载;边界条件;