首页> 外文期刊>Thin-Walled Structures >Structural behaviour and continuous strength method design of high strength steel non-slender welded Ⅰ-section beam-columns
【24h】

Structural behaviour and continuous strength method design of high strength steel non-slender welded Ⅰ-section beam-columns

机译:高强度钢非细长焊接Ⅰ段梁柱的结构行为和连续强度方法设计

获取原文
获取原文并翻译 | 示例
           

摘要

This paper presents the development of efficient design equations for high strength steel (HSS) welded I-section beam-columns under the framework of the Continuous Strength Method (CSM). The present work includes a collection of available experimental data on HSS S690 and S960 welded I-section beam-columns and a comprehensive numerical modelling programme considering a wider spectrum of parameters that influence the structural behaviour of the HSS welded I-section beam-columns. The developed FE models were first validated against test results collected from the literature, after which parametric studies were performed to generate further results to assess the accuracy of the codified design methods as used in Europe and the US, as well as to underpin new design proposals for HSS non-slender welded I-section beam-columns. It has been shown that the proposed CSM-based design approach is able to provide reliable design predictions with improved accuracy and reduced scatter over the existing design methods, and its reliability has been confirmed by means of statistical analyses.
机译:本文介绍了在连续强度法(CSM)框架下的高强度钢(HSS)焊接I型梁柱高效设计方程的发展。本工作包括关于HSS S690和S960焊接I截面梁柱的可用实验数据的集合以及考虑更广泛的参数的综合数值建模程序,这些参数影响了HSS焊接I剖面梁柱的结构行为。首先验证开发的FE模型,以防止从文献中收集的测试结果,之后进行参数研究以产生进一步的结果,以评估欧洲和美国的编纂设计方法的准确性,以及基于新的设计提案对于HSS非细长焊接I截面梁柱。已经表明,所提出的基于CSM的设计方法能够提供可靠的设计预测,提高了精度,并通过现有的设计方法减少散射,并且通过统计分析确认了其可靠性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号