With the purpose of introducing a new connection to cold-formed steel structure, this paper presents an experimental investigation of cold-formed steel (CFS) shear walls with self-piercing riveted (SPR) connections under monotonic and reversed cyclic loading. The effects of loading type (Monotonic and Cyclic), rivet spacing at the steel sheet edges, rivet number at CFS framing joints, axial compression ratio, and the steel sheathing types (steel sheet sheathing and corrugated steel sheathing) on mechanical behavior and failure modes of CFS shear walls were investigated. The shear strength, initial stiffness, and ductility of CFS shear walls with SPR connections were evaluated by comparing to the results of CFS shear walls with self-drilling screw connections under the same condition. Lateral loading, safety factor, and resistance factor under the wind and seismic loads were determined in accordance with test results of CFS shear wall with SPR connections. The research indicated that the rivet spacing at the sheet edges was a key factor affecting failure modes and mechanical properties of CFS shear walls. The relationship of shear strength and ultimate deformation decreased linearly with the increase of the rivet spacing. Compared to CFS shear walls with self-drilling screw, CFS shear walls with SPR have significantly improved shear strength and stiffness. Safety factor and resistance factor recommended by AISI Seismic Design Standard are conservative for the wind and seismic design of CFS shear wall using SPR connections.
机译:为了引入与冷弯钢结构的新连接,本文提出了在单调和反向循环荷载下具有自冲铆接(SPR)连接的冷弯钢(CFS)剪力墙的实验研究。载荷类型(单调和循环),钢板边缘的铆钉间距,CFS框架接缝处的铆钉数量,轴向压缩比以及钢护套类型(钢板护套和波纹钢护套)对机械性能和破坏模式的影响对CFS剪力墙进行了研究。通过与在相同条件下具有自钻螺钉连接的CFS剪力墙的结果进行比较,评估了带有SPR连接的CFS剪力墙的抗剪强度,初始刚度和延展性。根据带有SPR连接的CFS剪力墙的测试结果,确定了在风和地震荷载下的侧向荷载,安全系数和阻力系数。研究表明,板边缘的铆钉间距是影响CFS剪力墙破坏模式和力学性能的关键因素。剪切强度与极限变形的关系随着铆钉间距的增加而线性减小。与带有自钻螺钉的CFS剪力墙相比,带有SPR的CFS剪力墙具有显着改善的剪切强度和刚度。对于使用SPR连接的CFS剪力墙的风和地震设计,AISI抗震设计标准推荐的安全系数和抗力系数是保守的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号