首页> 外文期刊>Thermal engineering >Raising the Operational Reliability of the Steam Generator of a BN-600 Power Unit in Starting Regimes
【24h】

Raising the Operational Reliability of the Steam Generator of a BN-600 Power Unit in Starting Regimes

机译:在启动状态下提高BN-600动力装置蒸汽发生器的运行可靠性

获取原文
获取原文并翻译 | 示例
           

摘要

Experimental data are presented on the hydrodynamic instability of the steam-water flow in a once-through sodium-heated steam generator that occurs when the relative outlet enthalpy is more than unity. Effects of the time of operation on the change in the flow stability are revealed. Stability charts for the steam generator's evaporation modules are proposed, and recommendations for preventing the occurrence of instability in starting regimes are given.
机译:实验数据提供了当钠的相对出口焓大于1时发生的直流钠加热蒸汽发生器中蒸汽-水流的水动力不稳定性的信息。揭示了操作时间对流动稳定性变化的影响。提出了蒸汽发生器蒸发模块的稳定性图,并给出了防止启动状态下发生不稳定性的建议。

著录项

  • 来源
    《Thermal engineering》 |2006年第9期|p.733-736|共4页
  • 作者

    P. P. Govorov;

  • 作者单位

    Beloyarsk Nuclear Power Station, Zarechnyi, Sverdlovsk oblast, 624250 Russia;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 发电、发电厂;