首页> 外文期刊>Theoretical foundations of chemical engineering >Selection of Membranes for Deadend Micro- and Ultrafiltration Outside-In Hollow Fiber Filters
【24h】

Selection of Membranes for Deadend Micro- and Ultrafiltration Outside-In Hollow Fiber Filters

机译:末端微滤和超滤外入式中空纤维过滤器的膜选择

获取原文
获取原文并翻译 | 示例
       

摘要

A mathematical model taking into account the adsorption of particles around a membrane pore mouth at the stage of standard blocking is developed. The model is used to study the effect of the average membrane pore size, the cutoff coefficient, and the ratio of the length of the pore inlet region to be blocked to the whole pore length on the product flow rate of a deadend outside-in hollow fiber filter. It is shown that the use of membranes with an average pore size higher than the cutoff diameter for the particles to be removed from the suspension will be profitable only for the first 15-20 min of operation. In this case, the membrane should have an average pore size as large as possible, but not exceeding a limit value at which the membrane selectivity can drop; the cutoff coefficient as low as possible; and a pore inlet region to be blocked as long as possible.
机译:建立了在标准封闭阶段考虑颗粒在膜孔口周围吸附的数学模型。该模型用于研究平均膜孔径,截留系数以及要阻塞的孔入口区域的长度与整个孔长度的比率对空心内外死角产品流速的影响纤维过滤器。结果表明,对于从悬浮液中去除的颗粒,使用平均孔径大于截留直径的平均孔径的膜只会在操作的前15-20分钟内有利。在这种情况下,膜应具有尽可能大的平均孔径,但不超过膜选择性下降的极限值。截止系数尽可能低;并尽可能长地阻塞孔入口区域。