首页> 外文期刊>The Analyst >Septonex–tetraphenylborate screen-printed ion selective electrode for the potentiometric determination of Septonex in pharmaceutical preparations
【24h】

Septonex–tetraphenylborate screen-printed ion selective electrode for the potentiometric determination of Septonex in pharmaceutical preparations

机译:Septonex–硼酸四苯酯丝网印刷离子选择电极,用于电位计测定药物制剂中的Septonex

获取原文
获取原文并翻译 | 示例
       

摘要

A screen-printed electrode (SPE) was fabricated for the determination of 1-(ethoxycarbonyl)pentadecyltrimethylammonium bromide (Septonex) based on the use of Septonex–tetraphenylborate as the electroactive substance, and o-nitrophenyloctylether (o-NPOE) as the plasticizing agent. The electrode passes a near-Nernstian cationic slope of 59.33 ± 0.85 mV from activity between pH values of 2 to 9 with a lower detection limit of 9 × 10−7 M and response time of about 5 s and exhibits an adequate shelf-life of 6 months. The method was applied for the determination of Septonex in pharmaceutical preparations. A percentage recovery of 99.88% was obtained with RSD = 1.24%. The electrode was successfully applied in the determination of Septonex in laboratory-prepared samples by direct potentiometric, calibration curve and standard addition methods. Potentiometric titration of Septonex with sodium tetraphenylborate and phosphotungstic acid as a titrant was monitored with the modified screen-printed electrode as an end-point indicator electrode. Selectivity coefficients for Septonex relative to a number of potential interfering substances were determined. The sensor was highly selective for Septonex over a large number of compounds. Selectivity coefficient data for some common ions show negligible interference; however, cetyltrimethylammonium bromide and iodide ions interfere significantly. The analytical usefulness of the proposed electrode was evaluated by its application in the determination of Septonex in laboratory-prepared pharmaceutical samples with satisfactory results. The results obtained with the fabricated sensor are comparable with those obtained by the British Pharmacopeia method
机译:使用Septonex-四苯基硼酸酯作为电活性物质,并使用邻硝基苯基辛基醚(o-NPOE)作为增塑剂,制作了丝网印刷电极(SPE),用于测定1-(乙氧羰基)十五烷基三甲基溴化铵(Septonex)。 。电极从2到9的pH值之间的活性通过了一个接近能斯登的阳离子斜率,为59.33±0.85 mV,检测下限为9×10-7 M,响应时间约为5 s,并且具有足够的保质期。 6个月。该方法用于药物制剂中Septonex的测定。当RSD = 1.24%时,回收率达到99.88%。该电极已通过直接电位法,校正曲线和标准添加方法成功地用于测定实验室制备的样品中的Septonex。用修饰的丝网印刷电极作为终点指示电极,监测以四苯基硼酸钠和磷钨酸为滴定剂的Septonex的电位滴定。确定了Septonex相对于多种潜在干扰物质的选择性系数。该传感器对大量化合物对Septonex具有高度选择性。某些常见离子的选择性系数数据显示干扰可忽略不计;但是,十六烷基三甲基溴化铵和碘离子有明显的干扰。通过将拟议电极用于实验室制备的药物样品中的Septonex的测定,评估了该电极的分析实用性,结果令人满意。用装配好的传感器获得的结果与通过英国药典方法获得的结果相当

著录项

  • 来源
    《The Analyst》 |2011年第7期|p.1488-1495|共8页
  • 作者单位

    aChemistry Department, Faculty of Science, Cairo University, Giza, Egypt. E-mail: ggenidy@hotmail.com;

    Tel: +2 012 9160411bChemistry Department, Faculty of Science, Ain Shams University, Cairo, EgyptcDepartment of Petroleum Applications, Egyptian Petroleum Research Institute (EPRI), 1 Ahmed El-Zomor St., Nasr City, 11727, Cairo, Egypt;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

  • 入库时间 2022-08-17 13:14:47