Failure analysis of a thin-webbed girder of post-tensioned concrete

机译:后张混凝土薄腹梁的破坏分析

获取原文
获取原文并翻译 | 示例
           

摘要

The failure of a thin-webbed girder of post-tensioned concrete was investigated. In a foggy environment containing hydrochloric acid, the girder ruptured in the midspan as a result of steel strand corrosion. The causes and mechanisms of the strand fracture were identified by careful observations of the fracture surface of the strands and corrosion on the surface of the strands. Scanning electron microscopy (SEM) analysis of the fracture morphology of the strands, after mechanical fracture, showed that hydrogen in the environment had an effect on the strands. The investigation revealed that failure of the girder occurred because, while being attacked by the corrosive media, stress accelerated surface corrosion of the strands such that the cross-sections of the wires in the strands were severely weakened, consequently leading to the fracture of the strands.
机译:研究了后张法混凝土薄腹梁的破坏。在含有盐酸的多雾环境中,由于钢绞线腐蚀,大梁在中跨处破裂。通过仔细观察股线的断裂表面和股线表面的腐蚀,可以确定股线断裂的原因和机理。在机械断裂之后,对线的断裂形态的扫描电子显微镜(SEM)分析表明,环境中的氢对线具有影响。调查表明,梁的破坏是由于应力加速了绞合线的表面腐蚀,从而使绞合线中的导线横截面严重削弱,从而导致绞合线断裂,这是由于在受到腐蚀性介质的侵蚀时。