首页> 外文期刊>Sensors and materials >Fire Resistance of Concrete-Filled Box Columns Fabricated with Different Welding Methods
【24h】

Fire Resistance of Concrete-Filled Box Columns Fabricated with Different Welding Methods

机译:不同焊接方法制作的箱形混凝土柱的耐火性

获取原文
获取原文并翻译 | 示例
           

摘要

In this study, a series of two full-scale experiments were carried out to investigate the effects of welding method on the fire resistance of concrete-filled box columns (CFBCs). The column specimens were all square sections 500 x 500 mm~2 in size and 4350 mm high and were filled with high-strength concrete. Specimen CP1 was fabricated by a complete penetration weld while specimen PP1 was fabricated by a partial penetration weld. The tested columns were subjected to a constant compression load throughout the test period. The applied load corresponded to 28% of the design value of the buckling resistance of the column at room temperature. Test results indicate that the fire resistance of specimen CP1 was 55 min, compared with 51 min for specimen PP1. As a result, it can be concluded that under a load level of 0.28, the effect of different welding methods on the fire resistance of CFBC was not very significant. In addition, the established numerical model was able to reasonably predict the axial deformation of the tested columns.
机译:在这项研究中,进行了一系列的两个全面的实验,以研究焊接方法对混凝土箱形柱耐火性的影响。圆柱试样均为方形截面,尺寸为500 x 500 mm〜2,高4350 mm,并填充有高强度混凝土。试样CP1是通过完全熔透焊缝制造的,而试样PP1是通过部分熔透焊缝制造的。在整个测试期间,被测柱承受恒定的压缩载荷。施加的载荷相当于室温下圆柱抗屈曲设计值的28%。测试结果表明,试样CP1的耐火性为55分钟,而试样PP1为51分钟。结果可以得出结论,在0.28的载荷水平下,不同焊接方法对CFBC耐火性的影响不是很明显。此外,建立的数值模型能够合理地预测被测柱的轴向变形。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号