首页> 外文期刊>Sensors and Actuators >Non-dispersive infra-red (NDIR) measurement of carbon dioxide at 4.2 μm in a compact and optically efficient sensor
【24h】

Non-dispersive infra-red (NDIR) measurement of carbon dioxide at 4.2 μm in a compact and optically efficient sensor

机译:在紧凑且光学高效的传感器中以4.2μm的二氧化碳进行非分散红外(NDIR)测量

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Non-dispersive infra-red (NDIR) gas detection has enjoyed widespread uptake as a result of development of devices in the standard miniature format for gas sensors, consisting of a cylinder with external dimensions of 20 mm diameter × 16.5 mm height. We present a new design for such a sensor, making use of low-cost injection moulding technology. The design pays particular attention to the problem of maintaining a high optical throughput while providing an acceptable optical pathlength for gas detection. A detailed analysis of the design is presented, with the results of optical raytracing, showing a raytrace estimate for 4% of the total emitted radiation reaching each of two separated detector elements and a pathlength of 32 mm. Finally, we show experimental results obtained with as-manufactured devices, with a short-term limit of detection for carbon dioxide (CO_2) estimated at 1 ppm or a noise equivalent absorption (NEA) of 3 × 10~(-5) AU.
机译:由于开发了用于气体传感器的标准微型格式的设备,非分散红外(NDIR)气体检测得到了广泛的应用,该设备由外部尺寸为直径20 mm×高16.5 mm的圆柱体组成。我们使用低成本的注射成型技术为这种传感器提供了一种新设计。该设计特别注意在保持高光通量的同时为气体检测提供可接受的光程长度的问题。给出了对该设计的详细分析,并给出了光学射线追踪的结果,该结果显示了到达两个分离的探测器元件中的每一个的总发射辐射的4%的射线迹线估计,并且光程为32 mm。最后,我们展示了使用已制造的设备获得的实验结果,其中二氧化碳(CO_2)的短期检测极限估计为1 ppm或噪声等效吸收(NEA)为3×10〜(-5)AU。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号