This work focuses on the sensing performance of the sensor to chlorine (Cb) gas in air based on sodium super ionic conductor (NASICON) and oxide electrode. Among eight single oxides examined, Cr_2O_3 exhibited the highest sensitivity to Cl_2 gas in air at 300 ℃. △EMF values of the sensing device attached with Cr_2O_3 changed linearly with the logarithm of Cb concentration in the range of 5-50 ppm. The sensitivity of the sensors was testified by using Cr_2O_3 electrode sintered with different temperature. The sensor using Cr_2O_3 sintered at 600 C showed the largest sensitivity to Cl_2 at 300 ℃. Through burying the reference electrode in middle of the NASICON layer and decreasing the area of the reference electrode, the sensitivity of the sensor to Cb can be greatly improved. Finally, a sensing mechanism related to the mixed potential was proposed for the sensor based on NASICON and oxide electrode.
机译:这项工作的重点是基于钠超离子导体(NASICON)和氧化物电极的传感器对空气中氯(Cb)气体的传感性能。在八种单一氧化物中,Cr_2O_3在300℃的空气中对Cl_2气体表现出最高的敏感性。附着有Cr_2O_3的传感装置的△EMF值在5-50 ppm范围内随Cb浓度的对数线性变化。通过使用不同温度烧结的Cr_2O_3电极验证了传感器的灵敏度。 Cr_2O_3在600℃烧结的传感器在300℃时对Cl_2的敏感性最大。通过将参考电极埋在NASICON层的中间并减小参考电极的面积,可以大大提高传感器对Cb的灵敏度。最后,提出了一种基于NASICON和氧化物电极的混合电位传感器。

著录项

  • 来源
    《Sensors and Actuators》 |2013年第4期|66-70|共5页
  • 作者单位

    State Key Laboratory on Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012, China;

    State Key Laboratory on Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012, China;

    State Key Laboratory on Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012, China;

    State Key Laboratory on Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012, China;

    State Key Laboratory on Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012, China;

    State Key Laboratory on Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012, China;

    State Key Laboratory on Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012, China;

    State Key Laboratory on Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012, China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    NASICON; oxide electrode; Cl_2 sensor; buried reference electrode; mixed potential;

    机译:NASICON;氧化电极Cl_2传感器;埋入参比电极混合势;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号