The research is dedicated to the real-time studies detecting wall changes of Gram-positive bacteria Staphyloccoccus aureus using different amounts of antimicrobial agent benzylpenicillin (Benzylpenicillinum natricum-500,000 International Units/ml). The optical method based on excitation of the leaky mode in a sub-wavelength diffraction grating was employed. The proposed optical method is sensitive to the effective refractive index changes in vicinity of the sub-wavelength diffraction grating and it was used to study efficiency of the antimicrobial agent in situ. The bacterial solution (2.1 × 10~9 colony forming unit/ml S. aureus in 0.9% saline solution) was placed in a temperature-controlled measurement cell. Different amounts of benzylpenicillin were injected in the measurement cell and changes of the optical signature were monitored in vitro. The results obtained employing the optical method were verified comparing with the ones obtained employing standard microbiological tests and bacteria visualization by scanning electron microscopy (SEM). Samples for the microbiological tests and SEM analysis were taken from the liquid cell after injection of the antimicrobial agent. From the SEM micrographs, it was obtained that the cell wall morphological structure has been visibly changed after 0.2 ml and more of benzylpenicillin was applied. Changes in the optical signature of the proposed optical method in real time, i.e. the resonant wavelength shift and decrease in reflectivity, of the analyzed suspensions were addressed to the antimicrobial agent impact on the cell walls.
机译:该研究致力于使用不同量的抗菌剂苄青霉素(Benzylpenicillinum natricum-500,000 International Units / ml)检测革兰氏阳性细菌金黄色葡萄球菌壁变化的实时研究。采用基于激发亚波长衍射光栅中泄漏模式的光学方法。所提出的光学方法对亚波长衍射光栅附近的有效折射率变化敏感,并被用于原位研究抗菌剂的效率。将细菌溶液(2.1%10〜9个菌落形成单位/ ml金黄色葡萄球菌在0.9%盐溶液中)放入温度控制的测量池中。将不同量的苄青霉素注射到测量池中,并在体外监测光学标记的变化。通过光学方法获得的结果与通过标准微生物学测试和通过扫描电子显微镜(SEM)进行细菌可视化获得的结果进行了比较。注射抗微生物剂后,从液体池中获取用于微生物学测试和SEM分析的样品。从SEM显微照片可以看出,在加入0.2ml和更多的苄青霉素后,细胞壁的形态结构发生了明显变化。所提出的光学方法的光学特征的实时变化,即所分析的悬浮液的共振波长偏移和反射率降低,是针对抗微生物剂对细胞壁的影响而提出的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号