首页> 外文期刊>Sensors and Actuators >Few-layer graphene and polyaniline composite as ion-to-electron transducer in silicone rubber solid-contact ion-selective electrodes
【24h】

Few-layer graphene and polyaniline composite as ion-to-electron transducer in silicone rubber solid-contact ion-selective electrodes

机译:硅橡胶固体接触离子选择电极中的几层石墨烯和聚苯胺复合物作为离子电子转换器

获取原文
获取原文并翻译 | 示例
           

摘要

We have used for the first time a composite consisting of few-layer exfoliated graphene and electrically conducting polyaniline (PANI) as the ion-to-electron transducer (solid-contact) in Ca~(2+)-selective solid-contact electrodes (CaSCISEs). The drop cast transducer deposited from the graphene-PANI dispersion in N-methylpyrrolidone makes use of the synergistic effect of these two materials. It maintains the ion-to-electron transduction which is characteristic for the electrically conducting polymers (ECP), but in addition, graphene improves the reproducibility of the standard potential of the SClSEs compared to the neat PANI based electrodes and increases the hydrophobicity of the transducer (ca. 30° higher water contact angle) which counteracts the water layer formation. Our results reveal that the incorporation of few-layer graphene in the transducer layer improved also the initial potential stability and the response characteristics of the CaSCISEs due to the electrocatalytic effect of the graphene-ECP composite, which facilitates the electron transfer at the transducer/substrate interface. We obtained a potential reproducibility of only ±4 mV (n = 3) for the CaSCISEs having graphene-PANI as the solid-contact. The CaSCISEs in this study had a detection limit of 5 × 10~(-8) M Ca~(2+), which was obtained without any sophisticated pre-treatment protocols.
机译:我们首次使用由几层剥落的石墨烯和导电聚苯胺(PANI)组成的复合材料作为Ca〜(2+)选择性固体接触电极中的离子电子换能器(固体接触)( CaSCISE)。从石墨烯-PANI分散体在N-甲基吡咯烷酮中沉积的滴铸换能器利用了这两种材料的协同作用。它保持了导电聚合物(ECP)特有的离子电子转导,但是与基于PANI的纯电极相比,石墨烯提高了SClSEs标准电势的可再现性,并增加了传感器的疏水性(约30°高的水接触角)抵消了水层的形成。我们的结果表明,由于石墨烯-ECP复合材料的电催化作用,在换能器层中掺入了几层石墨烯还改善了CaSCISE的初始电势稳定性和响应特性,从而促进了换能器/衬底上的电子转移接口。对于以石墨烯-PANI作为固体触点的CaSCISE,我们获得的潜在重现性仅为±4 mV(n = 3)。本研究中的CaSCISE的检出限为5×10〜(-8)M Ca〜(2+),无需任何复杂的预处理方案即可获得。

著录项

  • 来源
    《Sensors and Actuators》 |2016年第3期|624-631|共8页
  • 作者

    Zhanna A. Boeva; Tom Lindfors;

  • 作者单位

    Abo Akademi University, Johan Gadolin Process Chemistry Centre, Faculty of Science and Engineering, Laboratory of Analytical Chemistry, Biskopsgatan 8, 20500 Abo, Turku, Finland,M.V. Lomonosov Moscow State University, Chemistry Department, Polymer Division, Leninskie Gory 1, Build. 3, 119991 Moscow, Russian Federation;

    Abo Akademi University, Johan Gadolin Process Chemistry Centre, Faculty of Science and Engineering, Laboratory of Analytical Chemistry, Biskopsgatan 8, 20500 Abo, Turku, Finland;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Solid-contact; Transducer; Ion-selective electrode; Few-layer graphene; Polyaniline; Standard reduction potential;

    机译:固体接触;传感器;离子选择电极;几层石墨烯;聚苯胺标准减排潜力;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号