...
首页> 外文期刊>Sensors and Actuators >Simultaneous voltammetric determination of antihypertensive drugs nifedipine and atenolol utilizing MgO nanoplatelet modified screen-printed electrodes in pharmaceuticals and human fluids
【24h】

Simultaneous voltammetric determination of antihypertensive drugs nifedipine and atenolol utilizing MgO nanoplatelet modified screen-printed electrodes in pharmaceuticals and human fluids

机译:MgO纳米血小板修饰的丝网印刷电极在药物和人体内液体中同时伏安法测定降压药硝苯地平和阿替洛尔

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Nifedipine and atenolol dugs are conjugated in several anti-hypertensive pharmaceutical formulations. Herein, a reproducible and sensitive voltammetric procedure has been developed for the simultaneous analysis of nifedipine and atenolol for the first time using MgO - nanoplatelets modified screen-printed electrodes (MgO - SPEs) via differential pulse voltammetry (DPV). Two very well-resolved and reproducible signals/oxidation peaks with a voltammetric separation of 0.35 V were obtained in Britton-Robinson (BR) buffer (pH 9). The MgO NPLs are found to exhibit a high electrocatalytic activity and improved voltammetric response compared to unmodified (bare) SPEs. Under optimum pH conditions (pH 9), the DPV curves exhibit linear responses to nifedipine and atenolol over the concentration ranges of 0.2-104.41 μM and 6.66-909.09 μM with detection limits of 0.032 μM and 1.76 μM, respectively. The applicability of the MgO-SPEs is successfully utilized for simultaneous determination of nifedipine and atenolol in pharmaceutical tablets and human urine samples with good accuracy and precision, these results agreeing with independent high-performance liquid chromatography (HPLC).
机译:硝苯地平和阿替洛尔的挖出物与几种抗高血压药物制剂共轭。本文中,已开发出一种可再现且灵敏的伏安法程序,首次使用MgO-纳米血小板修饰的丝网印刷电极(MgO-SPEs)通过差分脉冲伏安法(DPV)首次同时分析硝苯地平和阿替洛尔。在Britton-Robinson(BR)缓冲液(pH 9)中获得了两个很好分辨且可重现的信号/氧化峰,伏安法分离为0.35V。与未修饰的(裸)SPE相比,发现MgO NPL具有高的电催化活性和改进的伏安响应。在最佳pH条件(pH 9)下,DPV曲线在0.2-104.41μM和6.66-909.09μM的浓度范围内显示出对硝苯地平和阿替洛尔的线性响应,检出限分别为0.032μM和1.76μM。 MgO-SPEs的适用性已成功地用于药物片剂和人尿样品中的硝苯地平和阿替洛尔的同时测定,具有良好的准确性和精密度,这些结果与独立的高效液相色谱(HPLC)一致。

著录项

  • 来源
    《Sensors and Actuators》 |2017年第11期|1045-1054|共10页
  • 作者单位

    Chemistry Department. Faculty of Science, Sohag University, Sohag 82524, Egypt;

    Department of Pharmaceutical Analytical Chemistry, Faculty of pharmacy, Sohag University, Sohag 82524, Egypt,Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Assiut University, Assiut 71526, Egypt;

    Chemistry Department. Faculty of Science, Sohag University, Sohag 82524, Egypt;

    Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Assiut University, Assiut 71526, Egypt;

    Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Assiut University, Assiut 71526, Egypt;

    Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, Manchester, M1 5GD, UK;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Nifedipine; Atenolol; Magnesium oxide; Screen-printed electrodes; Antihypertensive; Nanoparticles;

    机译:硝苯地平阿替洛尔;氧化镁;丝网印刷电极;降压;纳米粒子;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号