In this work, a novel self-enhanced solid state electrochemiluminescence (ECU platform, based on poly-ethyleneimine (PEI) capped CdS quantum dots (PEI-CdS QDs) as coreactant and Au@SiO_2@Ru(bpy)_3~(2+) doped silica (Au@SiO_2@RuDS) nanocomposite as ECL emitter, was constructed. The PEI-CdS QDs integrated double coreactant of PEI and CdS QDs, thus significantly promoted the ECL of Au@SiO_2@RuDS. Polyaniline hydrogel was introduced to boost the electron transfer and to improve the immobilization of PEI-CdS/Au@SiO_2@RuDS. In addition, creatinine imprinted poly(o-aminophenol) film was electrodeposited on the PEI-CdS/Au@SiO_2@RuDS surface as recognition element. Thus, the obtained sensor possessed high sensitivity, stability, reproducibility and selectivity for creatinine sensing. The change of ECL intensity and logarithm of creatinine concentration showed a good linear relationship in the range of 0.05 nM to 5 uM, and the detection limit was low to 0.02 nM. The sensor was applied to detect creatinine in human serum and urine samples, and the results were in good agreement with those of commercial enzyme-linked immunosorbent assay kit.
机译:在这项工作中,一种新型的自增强固态电化学发光(ECU平台,基于聚乙基亚胺(PEI)封端的CDS量子点(PEI-CDS QD)作为成型和Au @ sio_2 @ ru(bpy)_3〜(2+构建了掺杂的二氧化硅(Au @ siO_2 @ ruds)纳米复合材料作为ECL发射器。PEI-CDS QDS的PEI和CDS QDS的双重固定剂,从而显着促进了Au @ SiO_2 @ Ruds的ECL。引入了聚苯胺水凝胶升压电子转移和改善PEI-CDS / Au @ SiO_2 @ ruds的固定化。此外,肌酐印迹聚(O-氨基苯酚)膜在PEI-CDS / Au @ SiO_2 @ ruds表面上被电沉积在识别元件上。从而,所获得的传感器具有高灵敏度,稳定性,再现性和对肌酐感测的可重复性和选择性。ECL强度和肌酐浓度的对数的变化在0.05nm至5μm的范围内显示出良好的线性关系,并且检测极限低至0.02 nm。将传感器应用于检测人血清和尿液样本中的肌酐,结果与商业酶联免疫吸附试剂盒吻合良好。

著录项

  • 来源
    《Sensors and Actuators》 |2020年第3期|127591.1-127591.7|共7页
  • 作者单位

    Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education) College of Chemistry and Molecular Sciences Wuhan University Wuhan 430072 Hubei Province PR China;

    Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education) College of Chemistry and Molecular Sciences Wuhan University Wuhan 430072 Hubei Province PR China;

    Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education) College of Chemistry and Molecular Sciences Wuhan University Wuhan 430072 Hubei Province PR China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Electrochemiluminescence; Tris(2,2'-bipyridine)-ruthenium(II); Polyethyleneimine; CdS quantum dots; Creatinine; Molecularly imprinting;

    机译:电化学荧光;TRIS(2,2'-Biphyridine) - 钌(II);聚乙烯亚胺;CDS量子点;肌酐;分子印迹;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号