...
首页> 外文期刊>Sensors and Actuators >Gold nanoparticle conjugated magnetic beads for extraction and nucleation based signal amplification in lateral flow assaying
【24h】

Gold nanoparticle conjugated magnetic beads for extraction and nucleation based signal amplification in lateral flow assaying

机译:金纳米颗粒共轭磁珠,用于横向流动测定中基于提取和成核的信号放大

获取原文
获取原文并翻译 | 示例
           

摘要

Analogues and interferents present in complex matrices like blood, plasma or serum influence lateral flow assay (LFA) responses, resulting in weak signals which compromise the limit of detection. Herein, we report a gold nanoparticle conjugated magnetic bead (GMB) based LFA approach for extraction and sensitive visual assaying of proteins in plasma. To validate the approach GMB, conjugated with anti-Troponin I antibodies, is used to capture cardiac marker Troponin I-C-T (cTnICT) in plasma that subsequently flows through on LFA membrane via a test zone containing anti-Troponin C antibodies. The capture of cTnICT-GMB complexes at the test zone produces a characteristic brownish band, enabling concentration dependent visual detection of cTnICT. Subsequently, contrast of these bands are enhanced by a nucleation approach, that utilizes the gold nanoparticles on GMB in the test bands as seed materials for growth of more visible gold clusters, improving visual detection limit of the assay to 0.1 ng/mL in plasma within 20min, using low sample volumes (< 100 uL). The proposed approach exploits the dual functionality of GMBs for efficient preconcentration and facile signal amplification. This assay offers a promising avenue for sensitive detection of analytes in complex matrices at clinically relevant concentrations without requiring tedious sample pre-treatment protocols.
机译:存在于复杂基质(例如血液,血浆或血清)中的类似物和干扰物会影响横向流测定(LFA)响应,从而导致信号微弱,从而损害了检测限。在此,我们报告了一种基于金纳米粒子共轭磁珠(GMB)的LFA方法,用于血浆中蛋白质的提取和灵敏的目测分析。为了验证该方法,与抗肌钙蛋白I抗体偶联的GMB用于捕获血浆中的心脏标记肌钙蛋白I-C-T(cTnICT),该血浆随后通过包含抗肌钙蛋白C抗体的测试区流经LFA膜。在测试区域捕获cTnICT-GMB复合物会产生特征性的褐色谱带,从而可以对cTnICT进行浓度依赖性视觉检测。随后,通过成核方法增强了这些谱带的对比度,该方法利用测试谱带中GMB上的金纳米颗粒作为种子材料,以生长更多可见的金簇,从而将测定的视觉检测极限提高到血浆中的0.1 ng / mL。使用少量样品(<100 uL)20分钟。所提出的方法利用了GMB的双重功能来进行有效的预浓缩和简便的信号放大。该测定法为灵敏检测复杂基质中临床相关浓度的分析物提供了一种有希望的途径,而无需繁琐的样品预处理方案。

著录项

  • 来源
    《Sensors and Actuators》 |2020年第6期|127959.1-127959.8|共8页
  • 作者单位

    Interdisciplinary Graduate School Nanyang Technological University 50 Nanyang Avenue 639798 Singapore School of Materials Science and Engineering Nanyang Technological University 50 Nanyang Avenue.639798 Singapore Center for Biomimetic Sensor Science Nanyang Technological University 50 Nanyang Drive 637553 Singapore;

    School of Materials Science and Engineering Nanyang Technological University 50 Nanyang Avenue.639798 Singapore;

    School of Materials Science and Engineering Nanyang Technological University 50 Nanyang Avenue.639798 Singapore Center for Biomimetic Sensor Science Nanyang Technological University 50 Nanyang Drive 637553 Singapore;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Lateral flow assay; Gold nanoparticles; Magnetic beads; Signal enhancement; Nucleation; Troponin assay;

    机译:横向流动分析;金纳米粒子;磁珠信号增强;成核;肌钙蛋白测定;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号