...
首页> 外文期刊>Sensors and Actuators >Cross-priming amplification combined with immunochromatographic strip for rapid on-site detection of African swine fever virus
【24h】

Cross-priming amplification combined with immunochromatographic strip for rapid on-site detection of African swine fever virus

机译:交叉引物扩增结合免疫色谱带可快速现场检测非洲猪瘟病毒

获取原文
获取原文并翻译 | 示例
           

摘要

African swine fever (ASF) is a highly contagious disease caused by African swine fever virus (ASFV) in domestic pigs and wild boars. Up to now, no commercial vaccines against ASF are available. With the rapid development of international trade and modern logistics and the frequent trade activities with Africa, Europe and neighboring countries, the risk of cross-border transmission of ASF to ASF-free regions is increasing. Therefore, there is an urgent need to establish a convenient and low-cost diagnostic method for rapid and on-site detection of the virus to timely implement the control measures. In this study, a cross-priming amplification in combination with immunochromatographic strip (CPA-strip) was established for rapid detection of ASFV. The CPA-strip assay displayed no cross-reactivity to other swine viruses. The minimum detection limit of this method was 200 copies. Forty-five clinical swine blood samples collected from Uganda were examined by the novel assay, 6 out of 45 samples were tested positive for ASFV. The agreement rate between the CPA-strip assay and the universal probe library-based real-time PCR was 97.8% (44/45). In addition, a total of 100 tissue samples and 57 blood samples from Chinese swine herds were tested to be negative. We concluded that the established CPA-strip method is suitable for on-site detection of ASFV.
机译:非洲猪瘟(ASF)是一种由非洲猪瘟病毒(ASFV)在家猪和野猪中引起的高度传染性疾病。到目前为止,尚无针对ASF的商业疫苗。随着国际贸易和现代物流的迅速发展以及与非洲,欧洲和邻国的频繁贸易活动,ASF跨境传播到无ASF地区的风险正在增加。因此,迫切需要建立一种方便,低成本的诊断方法,以快速,现场地检测出病毒,以便及时实施控制措施。在这项研究中,交叉引物扩增结合免疫层析带(CPA-strip)被建立用于快速检测ASFV。 CPA条分析显示与其他猪病毒无交叉反应。该方法的最低检测限为200份。通过该新方法检测了从乌干达收集的45份临床猪血样本,其中45份样本中有6份被检测为ASFV阳性。 CPA-Strip检测与基于通用探针库的实时PCR的一致性率为97.8%(44/45)。此外,来自中国猪群的总共100个组织样本和57个血液样本被检测为阴性。我们得出的结论是,已建立的CPA-Strip方法适用于ASFV的现场检测。

著录项

  • 来源
    《Sensors and Actuators》 |2018年第11期|304-309|共6页
  • 作者单位

    State Key Laboratory of Veterinary Biotechnology, Harbin Veterinary Research Institute, Chinese Academy of Agricultural Sciences;

    State Key Laboratory of Veterinary Biotechnology, Harbin Veterinary Research Institute, Chinese Academy of Agricultural Sciences;

    State Key Laboratory of Veterinary Biotechnology, Harbin Veterinary Research Institute, Chinese Academy of Agricultural Sciences;

    State Key Laboratory of Veterinary Biotechnology, Harbin Veterinary Research Institute, Chinese Academy of Agricultural Sciences;

    State Key Laboratory of Veterinary Biotechnology, Harbin Veterinary Research Institute, Chinese Academy of Agricultural Sciences;

    State Key Laboratory of Veterinary Biotechnology, Harbin Veterinary Research Institute, Chinese Academy of Agricultural Sciences;

    State Key Laboratory of Veterinary Biotechnology, Harbin Veterinary Research Institute, Chinese Academy of Agricultural Sciences;

    State Key Laboratory of Veterinary Biotechnology, Harbin Veterinary Research Institute, Chinese Academy of Agricultural Sciences;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    African swine fever virus; Cross-priming amplification; Immunochromatographic strip; On-site detection;

    机译:非洲猪瘟病毒;交叉引物扩增;免疫层析带;现场检测;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号