首页> 外文期刊>Semiconductor photonics and technology >Positioning Error of Optoelectronic Telescope Compensated by Bipolar PWM Driving Mode
【24h】

Positioning Error of Optoelectronic Telescope Compensated by Bipolar PWM Driving Mode

机译:双极PWM驱动模式补偿光电望远镜的定位误差

获取原文
获取原文并翻译 | 示例

摘要

The optoelectronic telescope has two sets of control systems: azimuth one and elevation one, and both are driven by PWM power amplifier with high efficiency and wide speed regulation range. The diagram of the azimuth control system is demonstrated, the nonlinear factors is analyzed at low speed, and some related experiments are carried out. The results show that the positioning error with unipolar is 86 codes(106. 21"), while 18 codes (22. 23") is with bipolar PWM driver.
机译:光电望远镜有两套控制系统:方位角一和仰角一律,均由PWM功率放大器驱动,效率高,调速范围大。演示了方位控制系统的原理图,分析了低速时的非线性因素,并进行了一些相关的实验。结果表明,单极性的定位误差为86码(106. 21“),而双极性PWM驱动器为18码(22. 23”)。