The aim of the present work is to study the occupants' exposure to fine particulate concentrations in ten nightclubs (NCs) in Athens, Greece. Measurements of PM_1 and PM_(2.5) were made in the outdoor and indoor environment of each NC. The average indoor PM_1 and PM2.5 concentrations were found to be 181.77 μg m~(-3) and 454.08 μg m~(-3) respectively, while the corresponding outdoor values were 11.04 μg m~(-3) and 32.19 μg m~(-3). Ventilation and resuspension rates were estimated through consecutive numerical experiments with an indoor air quality model and were found to be remarkably lower than the minimum values recommended by national standards. The relative effects of the ventilation and smoking on the occupants' exposures were examined using multiple regression techniques. It was found that given the low ventilation rates, the effect of smoking as well as the occupancy is of the highest importance. Numerical evaluations showed that if the ventilation rates were at the minimum values set by national standards, then the indoor exposures would be reduced at the 70% of the present exposure values.
机译:当前工作的目的是研究希腊雅典十家夜总会(NC)中乘员暴露于细颗粒物浓度的情况。在每个NC的室外和室内环境中测量PM_1和PM_(2.5)。室内平均PM_1和PM2.5的平均浓度分别为181.77μgm〜(-3)和454.08μgm〜(-3),相应的室外值为11.04μgm〜(-3)和32.19μgm 〜(-3)。通过室内空气质量模型的连续数值实验估算了通风和再悬浮率,发现其明显低于国家标准建议的最小值。使用多重回归技术检查了通风和吸烟对乘员暴露的相对影响。人们发现,由于通风率低,吸烟和占用率的影响最为重要。数值评估表明,如果通风率处于国家标准设定的最小值,则室内暴露量将减少为当前暴露量的70%。

著录项

  • 来源
    《Science of the total environment》 |2009年第17期|4894-4901|共8页
  • 作者单位

    Department of Environmental Physics and Meteorology, Faculty of Physics, University of Athens, Building Phys 5, University Campus, Athens, 15784 Greece;

    Department of Environmental Physics and Meteorology, Faculty of Physics, University of Athens, Building Phys 5, University Campus, Athens, 15784 Greece;

    Department of Environmental Physics and Meteorology, Faculty of Physics, University of Athens, Building Phys 5, University Campus, Athens, 15784 Greece;

    Faculty of Engineering, University of Porto, MIT-Portugal;

    Department of Environmental Physics and Meteorology, Faculty of Physics, University of Athens, Building Phys 5, University Campus, Athens, 15784 Greece;

    Department of Environmental Physics and Meteorology, Faculty of Physics, University of Athens, Building Phys 5, University Campus, Athens, 15784 Greece;

    Department of Environmental Physics and Meteorology, Faculty of Physics, University of Athens, Building Phys 5, University Campus, Athens, 15784 Greece;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    indoor exposure; resuspension; ventilation; nightclubs; PM_1; PM_(2.5);

    机译:室内暴露;重新悬浮;通风;夜总会;PM_1;PM_(2.5);
  • 入库时间 2022-08-17 13:57:34

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号