首页> 外文期刊>Review of Scientific Instruments >Manufacturing of 50 kA superconducting transformer for ITER correction coil conductor test
【24h】

Manufacturing of 50 kA superconducting transformer for ITER correction coil conductor test

机译:用于ITER校正线圈导体测试的50 kA超导变压器的制造

获取原文
获取原文并翻译 | 示例
       

摘要

To meet the specifications of International Thermonuclear Experimental Reactor correction coil (CC) conductor, a 50 kA superconducting transformer has been designed and manufactured to provide the short sample of the CC conductor the current. The transformer consists of two concentric layer-wound superconducting solenoids with the primary inside the secondary coil. In order to test the transformer, the two legs of the secondary coil were directly connected by superconducting cables. A 500 W/4.5 K refrigerator was used to provide the supercritical helium. The maximum current of 56.3 kA in the secondary coil loop was obtained. © 2010 American Institute of Physics Article Outline INTRODUCTION BASIC DESIGN MANUFACTURING OF SUPERCONDUCTING TRANSFORMER Transformer Dewar 200 A high temperature superconducting current lead Joint fabrication Manufacture of primary and secondary coils TEST CONCLUSIONS
机译:为了满足国际热核实验堆校正线圈(CC)导体的规范,已设计并制造了50 kA超导变压器,以向CC导体的短样本提供电流。变压器由两个同心绕层超导螺线管组成,初级线圈位于次级线圈内。为了测试变压器,次级线圈的两个支脚通过超导电缆直接连接。使用500 W / 4.5 K的冰箱提供超临界氦气。在次级线圈环路中获得的最大电流为56.3 kA。 ©2010美国物理研究所文章大纲简介超导变压器的基本设计制造变形金刚杜瓦200高温超导电流引线联合制造一次和二次线圈的制造测试结论