...
首页> 外文期刊>Review of Scientific Instruments >Development of the scintillator-based probe for fast-ion losses in the HL-2A tokamak
【24h】

Development of the scintillator-based probe for fast-ion losses in the HL-2A tokamak

机译:基于闪烁体的HL-2A托卡马克中快速离子损失探针的开发

获取原文
获取原文并翻译 | 示例
           

摘要

A new scintillator-based lost fast-ion probe (SLIP) has been developed and operated in the HL-2A tokamak [L. W. Yan, X. R. Duan, X. T. Ding, J. Q. Dong, Q. W. Yang, Yi Liu, X. L. Zou, D. Q. Liu, W. M. Xuan, L. Y. Chen, J. Rao, X. M. Song, Y. Huang, W. C. Mao, Q. M. Wang, Q. Li, Z. Cao, B. Li, J. Y. Cao, G. J. Lei, J. H. Zhang, X. D. Li, W. Chen, J. Chen, C. H. Cui, Z. Y. Cui, Z. C. Deng, Y. B. Dong, B. B. Feng, Q. D. Gao, X. Y. Han, W. Y. Hong, M. Huang, X. Q. Ji, Z. H. Kang, D. F. Kong, T. Lan, G. S. Li, H. J. Li, Qing Li, W. Li, Y. G. Li, A. D. Liu, Z. T. Liu, C. W. Luo, X. H. Mao, Y. D. Pan, J. F. Peng, Z. B. Shi, S. D. Song, X. Y. Song, H. J. Sun, A. K. Wang, M. X. Wang, Y. Q. Wang, W. W. Xiao, Y. F. Xie, L. H. Yao, D. L. Yu, B. S. Yuan, K. J. Zhao, G. W. Zhong, J. Zhou, J. C. Yan, C. X. Yu, C. H. Pan, Y. Liu, and the HL-2A Team, Nucl. Fusion 51, 094016 (2011)] to measure the losses of neutral beam ions. The design of the probe is based on the concept of the α-particle detectors on Tokamak Fusion Test Reactor (TFTR) using scintillator plates. The probe is capable of traveling across an equatorial plane port and sweeping the aperture angle rotationally with respect to the axis of the probe shaft by two step motors, in order to optimize the radial position and the collimator angle. The energy and the pitch angle of the lost fast ions can be simultaneously measured if the two-dimensional image of scintillation light intensity due to the impact of the lost fast ions is detected. Measurements of the fast-ion losses using the probe have been performed during HL-2A neutral beam injection discharges. The clear experimental evidence of enhanced losses of beam ions during disruptions has been obtained by means of the SLIP system. A detailed description of the probe system and the first experimental results are reported
机译:在HL-2A托卡马克中已开发并使用了一种基于闪烁体的新型丢失快速离子探针(SLIP)[L.严W.段小刚,丁XT,董继强,杨庆伟,刘毅,邹祖,,刘大庆,宣威,吕立晨,饶志明,宋晓明,黄玉,毛伟华,王QM。李志。,曹B,曹J,雷国强,张建华,李晓东,陈维,陈杰,崔春水,崔志远,邓建中,董玉宝,冯BB,高QD,韩XY ,洪伟,黄明,纪小青,康康,孔东风,兰涛,李国柱,李庆杰,李青,李文伟,李玉格,刘AD,刘中涛,罗伟武,毛秀华,YD潘鹏鹏彭世邦SD SD宋宋XYJH孙王AK MX王王群Q WWW肖萧谢芳FY姚宇DL袁媛BS Zhao KJ Zhao GW Zhong J. ,JC Yan,CX Yu,CH CH Pan,Y。Liu和HL-2A小组(Nucl。 Fusion 51,094016(2011)]来测量中性束离子的损失。探针的设计基于使用闪烁器板的托卡马克聚变测试反应堆(TFTR)上的α粒子探测器的概念。探头能够跨过赤道平面端口并通过两个步进电机相对于探头轴的轴线旋转扫描孔径角,以优化径向位置和准直器角度。如果检测到由于丢失的快离子的冲击而产生的闪烁光强度的二维图像,则可以同时测量丢失的快离子的能量和俯仰角。在HL-2A中性束注入放电期间,已经使用探针测量了快速离子损失。通过SLIP系统已经获得了在破坏过程中增加束离子损失的明确实验证据。报告了探针系统的详细说明和第一个实验结果

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号