首页> 外文期刊>Renewable Power Generation, IET >Open-circuit faults diagnosis in back-to-back converters of DF wind turbine
【24h】

Open-circuit faults diagnosis in back-to-back converters of DF wind turbine

机译:DF风力发电机背靠背变频器中的开路故障诊断

获取原文
获取原文并翻译 | 示例

摘要

The open-circuit fault in converters is one of the wind turbine faults, which degrades the power quality and can even cause potential secondary faults in other components. So, an effective fault diagnostic technique for wind turbine converters is needed. This study presents a new open-circuit fault diagnostic approach for back-to-back converters of doubly fed (DF) wind turbines. The proposed fault diagnostic method has fault detection and fault localisation. The fault detection is based on the absolute normalised Park's vector approach; this method can detect multiple open-circuit switch faults and guarantee immunity to false alarms when the DF induction generator operates around the synchronous speed. For fault localisation, this approach applies the normalised current average values, which can be used to identify single and double open-circuit switch faults. The simulation and experimental results indicate that the diagnostic method can not only diagnose multiple open-circuit faults, but that false alarms due to transients can be avoided.
机译:变流器中的开路故障是风力涡轮机故障之一,这会降低电能质量,甚至可能在其他组件中引起潜在的二次故障。因此,需要一种用于风力涡轮机转换器的有效故障诊断技术。这项研究为双馈(DF)风力发电机的背靠背转换器提出了一种新的开路故障诊断方法。提出的故障诊断方法具有故障检测和故障定位功能。故障检测基于绝对归一化的Park向量法。这种方法可以检测多个开路开关故障,并确保当DF感应发电机以同步速度运行时不会出现虚假警报。对于故障定位,此方法应用归一化的电流平均值,该平均值可用于识别单开路和双开路开关故障。仿真和实验结果表明,该诊断方法不仅可以诊断多个开路故障,而且可以避免由于瞬态引起的误报。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号