A Case Study Of Underground Thermal Storage In A Solar-ground Coupled Heat Pump System For Residential Buildings

机译:住宅建筑太阳能-地面耦合热泵系统中地下蓄热的案例研究

获取原文
获取原文并翻译 | 示例
       

摘要

This paper presents a case study of underground thermal storage in a solar-ground coupled heat pump system (SGCHPS) for residential buildings. Based on the experimental results, the operation performance is simulated by the unit modelling. The results show that the performance of underground thermal storage of SGCHPS depends strongly on the intensity of the solar radiation and the matching between the water tank volume and the area of solar collectors. Compared with the solar radiation, the variations of the water tank temperature and the ground temperature raise lag behind and keep several peaks during the day time. In the present study, the experimental efficiency of underground thermal storage based on the absorbed solar energy by the collectors reaches 76%. For the similar design of SGCHPS, it is suggested that the optimal ratio between the tank volume and the area of solar collectors should range from 20 to 40 L/m~2.
机译:本文介绍了一个用于住宅建筑的太阳能地面耦合热泵系统(SGCHPS)中地下蓄热的案例研究。根据实验结果,通过单元建模来模拟操作性能。结果表明,SGCHPS的地下蓄热性能在很大程度上取决于太阳辐射强度以及水箱容积与集热器面积之间的匹配。与太阳辐射相比,水箱温度和地面温度的变化滞后,并在白天保持几个峰值。在本研究中,基于集热器吸收的太阳能的地下蓄热实验效率达到76%。对于SGCHPS的类似设计,建议水箱容积与太阳能集热器面积的最佳比例应在20至40 L / m〜2的范围内。