首页> 外文期刊>Renewable energy >Experimental evaluation of ventilated walls with an external clay cladding
【24h】

Experimental evaluation of ventilated walls with an external clay cladding

机译:外部粘土砌面通风墙的实验评估

获取原文
获取原文并翻译 | 示例
       

摘要

The paper presents the results of an experimental study on ventilated walls with an external clay cladding in a temperate Mediterranean climate.The aim of this work is to assess the actual thermal performance of the ventilated facade with a complete thermo-fluid dynamic analysis. The paper describes the experimental work carried out on walls with different exposure and various heights of the ventilation channel (6 m and 12 m) with controlled internal air temperature. The air velocities, temperatures and heat fluxes in the ventilated facade were monitored and correlations between the thermo-physical parameters were identified.The study showed that, on sunny days, the external surface temperatures, temperatures in the air cavity and air velocity in the gap are considerably higher for the 12 m wall, while during the nighttime lower temperatures are found for the various layers of the wall.The data obtained allowed us to calculate the Reynolds number and to identify the airflow rate in the channel. Correlations were found between the air velocity in the gap, the airflow rate, the Reynolds number and the sun-air temperature. These correlations are useful for modelling ventilated walls, which are generally very complex, with simplified equivalent walls. Finally it was possible to identify the peak temperatures with respect to exposure and thermal lag. The thermo-graphic analysis showed that the behaviour of the walls is almost uniform without thermal bridges.
机译:本文介绍了在地中海温带气候下使用外部粘土覆层的通风墙的实验研究结果,旨在通过完整的热流体动力学分析来评估通风外墙的实际热性能。本文描述了在室内空气温度受控的情况下,在具有不同暴露量和通风通道高度(6 m和12 m)的墙壁上进行的实验工作。监测通风外墙的风速,温度和热通量,并确定热物理参数之间的相关性。研究表明,在晴天时,外表面温度,气腔温度和缝隙中的空气速度对于12 m的墙壁,其温度要高得多,而在夜间,墙壁的各个层的温度都较低。获得的数据使我们能够计算雷诺数并确定通道中的气流速率。发现间隙中的空气速度,气流速率,雷诺数和太阳气温之间存在相关性。这些关联对于通气墙建模非常有用,通气墙通常非常复杂,具有简化的等效墙。最后,可以确定相对于暴露和热滞后的峰值温度。热成像分析表明,在没有热桥的情况下,壁的行为几乎是均匀的。

著录项

  • 来源
    《Renewable energy》 |2011年第12期|p.3373-3385|共13页
  • 作者单位

    Department of Architecture. Construction and Structures (DACS), Faculty of Engineering, Polytechnic University of Marche, Via Brecce Bianche, 60131 Ancona, Italy;

    Department of Architecture. Construction and Structures (DACS), Faculty of Engineering, Polytechnic University of Marche, Via Brecce Bianche, 60131 Ancona, Italy;

    Department of Architecture. Construction and Structures (DACS), Faculty of Engineering, Polytechnic University of Marche, Via Brecce Bianche, 60131 Ancona, Italy;

    Department of Energy, Faculty of Engineering, Polytechnic University ofMarche, Via Brecce Bianche, 60131 Ancona, Italy;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    ventilated facade; experimental study; thermal performance; energy saving; ventilation channel; temperature distribution;

    机译:通风外墙;实验研究;热性能;节能;通风通道;温度分布;