Purpose: To evaluate the effectiveness of the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) technique for superparamagnetic iron oxide (SPIO)-enhanced T2-weighted magnetic resonance (MR) imaging with respiratory compensation with the prospective acquisition correction (PACE) technique in the detection of hepatic lesions. Materials and Methods: The institutional human research committee approved this prospective study, and all patients provided written informed consent. Eighty-one patients (mean age, 58 years) underwent hepatic 1.5-T MR imaging. Fat-saturated T2-weighted turbo spin-echo images were acquired with the PACE technique and with and without the PROPELLER method after administration of SPIO. Images were qualitatively evaluated for image artifacts, depiction of liver edge and intrahepatic vessels, overall image quality, and presence of lesions. Three radiologists independently assessed these characteristics with a five-point confidence scale. Diagnostic performance was assessed with receiver operating characteristic (ROC) curve analysis. Quantitative analysis was conducted by measuring the liver signal-to-noise ratio (SNR) and the lesion-to-liver contrast-to-noise ratio (CNR). The Wilcoxon signed rank test and two-tailed Student t test were used, and P < .05 indicated a significant difference. Results: MR imaging with the PROPELLER and PACE techniques resulted in significantly improved image quality, higher sensitivity, and greater area under the ROC curve for hepatic lesion detection than did MR imaging with the PACE technique alone (P < .001). The mean liver SNR and the lesion-to-liver CNR were higher with the PROPELLER technique than without it (P < .001). Conclusion: T2-weighted MR imaging with the PROPELLER and PACE technique and SPIO enhancement is a promising method with which to improve the detection of hepatic lesions. © RSNA, 2009
机译:目的:利用前瞻性采集校正(PACE)技术,评估具有增强重建功能的周期性旋转重叠平行线(PROPELLER)技术对具有呼吸补偿的超顺磁性氧化铁(SPIO)增强的T2加权磁共振(MR)成像的有效性在检测肝脏病变中。材料和方法:机构人类研究委员会批准了该前瞻性研究,所有患者均提供了书面知情同意书。八十一例患者(平均年龄58岁)接受了肝脏1.5-T MR成像。给予SPIO后,使用PACE技术以及使用和不使用PROPELLER方法获取脂肪饱和的T2加权涡轮自旋回波图像。定性评估了图像的图像伪影,肝边缘和肝内血管的描绘,整体图像质量以及病变的存在。三名放射科医生以五点置信度表独立评估了这些特征。通过接收器工作特性(ROC)曲线分析评估诊断性能。通过测量肝脏的信噪比(SNR)和病灶-肝脏的对比噪声比(CNR)进行定量分析。使用Wilcoxon符号秩检验和两尾Student t检验,P <.05表示有显着差异。结果:与仅使用PACE技术的MR成像相比,使用PROPELLER和PACE技术的MR成像可显着改善图像质量,更高的灵敏度以及ROC曲线下的肝病变检测面积更大(P <.001)。采用PROPELLER技术的平均肝脏SNR和病变至肝脏的CNR高于未采用该技术的患者(P <.001)。结论:采用PROPELLER和PACE技术以及SPIO增强的T2加权MR成像是改善肝病变检测的一种有前途的方法。 ©RSNA,2009年

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号