Since 1974, many Wisconsin Test Facility (WTF) phasing anomalies have been observed. Among these anomalies are (a) ° phasing does not equal (360° - °) phasing, contrary to the normal behavior of crossed dipoles; (b) the maximum field strength at any single receiving location does not occur when = 0 or 180°; (c) the WTF antenna phasing shift appears to be -20° to -30°; (d) the WTF effective dipole moment does not appear to be independent of ; and (e) the WTF antenna phasing shift appears to be a function of azimuth angle. By a combination of near-field and far-field measurements, we have determined empirically a new WTF pattern factor that quantitatively describes these anomalies.
机译:自1974年以来,已经观察到许多威斯康星州测试设施(WTF)的定相异常。在这些异常中:(a)相角不等于(360°-°)相角,这与交叉偶极子的正常行为相反; (b)当= 0或180°时,在任何单个接收位置都不会出现最大场强; (c)WTF天线的相移似乎为-20°至-30°; (d)WTF有效偶极矩似乎并不独立于; (e)WTF天线的相移似乎是方位角的函数。通过近场和远场测量的组合,我们凭经验确定了一种新的WTF模式因子,可以定量描述这些异常。