首页> 外文期刊>Radiation Protection and Environment >Dosimetric analysis of intensity modulated radiotherapy plans having one or more pairs of parallel opposed beams among the set of beams in some special cases
【24h】

Dosimetric analysis of intensity modulated radiotherapy plans having one or more pairs of parallel opposed beams among the set of beams in some special cases

机译:在某些特殊情况下,在一组光束中具有一对或多对平行的相对光束的强度调制放射治疗计划的剂量学分析

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The purpose of this study was to analyze the dosimetric parameters of intensity modulated radiotherapy (IMRT) plans with a set of beams having one or more pairs of parallel opposed beams for the pelvis, head-and-neck (H and N) and brain cases having large secondary nodes. We selected three pelvis (carcinoma of prostate with pelvic bony mets), three H and N (two cases of carcinoma of the parotid with large secondary nodes and one case of carcinoma of the base of the tongue with large secondary nodes), and three brain (glioblastoma multiform) IMRT patients. IMRT plans were done with a set of 6-9 beams having one or more pairs of parallel opposed beams. Each plan was done using 6 MV photon energy. Each plan was analyzed on the basis of planning target volume (PTV) coverage with 93%, 95%, 100%, 107%, and 110% of the prescribed dose (PD), organs at risk (OAR) doses, homogeneity index (HI), conformity index (CI), and normal tissue integral dose (NTID). The doses to OARs were well within tolerance limits and the PTV coverage for 93%, 95%, and 100% of PD was obtained very well (followed the radiation therapy oncology group criteria "95% and 99% volume of PTV should receive 95% and 93% of the PD, respectively"), and values of HI, CI, and NTID were also satisfactory. In summary, very good OAR sparing and PTV coverage were observed in all plans. Hence, it can be concluded that use of one or more pairs of parallel opposed beams in IMRT plans in some special cases as selected for this study offers the benefit in terms of critical target volume irradiation, while maintaining the OAR within tolerable limits.
机译:这项研究的目的是分析用于骨盆,头颈(H和N)和脑部情况的一组具有一对或多对平行相对光束的光束的强度调制放射治疗(IMRT)计划的剂量参数具有较大的辅助节点。我们选择了三个骨盆(前列腺癌伴盆腔骨s),三个H和N(两个腮腺癌伴次要结节较大的病例和一个舌根癌伴有次要结节较大的病例)和三个脑(成胶质细胞瘤形式)IMRT患者。 IMRT计划是通过一组6-9个光束完成的,这些光束具有一对或多对平行的相对光束。每个计划都是使用6 MV光子能量完成的。根据计划目标量(PTV)覆盖率对每个计划进行分析,覆盖率分别为规定剂量(PD)的93%,95%,100%,107%和110%,高危器官(OAR)剂量,均一性指标( HI),合格指数(CI)和正常组织积分剂量(NTID)。 OARs的剂量完全在耐受范围内,并且获得93%,95%和100%PD的PTV覆盖率非常好(按照放射治疗肿瘤学小组的标准,“ PTV的95%和99%体积应接受95%和分别为PD的93%”和HI,CI和NTID的值也令人满意。总之,在所有计划中都观察到非常好的OAR保留和PTV覆盖范围。因此,可以得出结论,在本研究选择的某些特殊情况下,在IMRT计划中使用一对或多对平行的相对光束在临界目标体积辐照方面提供了好处,同时将OAR维持在可容忍的范围内。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号