The Institute for Radiological Protection and Nuclear Safety owns two facilities producing realistic mixed neutron-photon radiation fields, CANEL, an accelerator driven moderator modular device, and SIGMA, a graphite moderated americium-beryllium assembly. These fields are representative of some of those encountered at nuclear workplaces, and the corresponding facilities are designed and used for calibration of various instruments, such as survey meters, personal dosimeters or spectro-metric devices. In the framework of the European project EVIDOS, irradiations of personal dosimeters were performed at CANEL and SIGMA. Monte Carlo calculations were performed to estimate the reference values of the personal dose equivalent at both facilities. The H_p(10) values were calculated for three different angular positions, 0°, 45° and 75°, of an ICRU phantom located at the position of irradiation.
机译:放射防护与核安全研究所拥有两个生产现实中子-光子混合辐射场的设施,一个是CANEL,一个加速器驱动的减速器模块化设备,另一个是SIGMA,一个石墨缓和的a-铍组件。这些领域代表了核工作场所遇到的一些领域,相应的设施被设计并用于各种仪器的校准,例如测量仪,个人剂量计或光谱仪。在欧洲项目EVIDOS的框架内,在CANEL和SIGMA进行了个人剂量计的辐照。进行了蒙特卡洛计算,以估计两个机构的个人剂量当量的参考值。针对位于照射位置的ICRU体模的三个不同角度位置(0°,45°和75°)计算H_p(10)值。