An optimal algorithm, which suitably combines two dosemeter readings, one dosemeter on the chest and the other on the back, for better estimation of effective dose equivalent(H_E) and effective dose (E).was developed by utilising hundreds of broad parallel photon beam irradiation geometries. The developed algorithm, weighting front (chest)and back dosemeter readings by 0.58 and 0.42, respectively, was found to be superior to other currently available algorithms, neither underestimating H_E or E by more than 14, nor overestimating by more than a few tens of a per cent for a broad range of frontal and dorsal incident beams. Like other algorithms, however, this algorithm tends to overestimate H_E and E significantly for the lateral, overhead and underfoot beam directions. This study also suggests that this overestimation problem significantly decreases when one uses typical commercial dosemeters instead of isotropic-responding dosemeters.
机译:通过利用数百个宽平行光子束,开发了一种最佳算法,该算法适当地结合了两个剂量计读数,一个剂量计位于胸部,另一个剂量计位于背面,以便更好地估算有效剂量当量(H_E)和有效剂量(E)。辐射几何形状。发现开发的算法分别将前(胸)和后剂量计读数加权0.58和0.42,这优于其他当前可用的算法,既不会低估H_E或E超过14,也不会高估数十倍范围广泛的正面和背面入射光束的百分比。但是,像其他算法一样,该算法往往会在横向,头顶和脚下波束方向上高估H_E和E。这项研究还表明,当人们使用典型的商用剂量计而不是各向同性剂量计时,这种高估问题会大大减少。