data are currently being collected from hospital radiology information systems in the north west of the uk for the purposes of both clinical audit and patient dose audit. Could these data also be used to satisfy quality assurance (qa) requirements according to uk guidance? From 2008 to 2009; 731 653 records were submitted from 8 hospitals from the north west england. For automatic exposure control qa; the protocol from institute of physics and engineering in medicine (ipem) report 91 recommends that milliamperes per second can be monitored for repeatability and reproducibility using a suitable phantom; at 70-81 kv. Abdomen ap and chest pa examinations were analysed to find the most common kilovoltage used with these records then used to plot average monthly milliamperes per second with time. Ipem report 91 also recommends that a range of commonly used clinical settings is used to check output reproducibility and repeatability. For each tube; the dose area product values were plotted over time for two most common exposure factor sets. Results show that it is possible to do performance checks of aec systems; however more work is required to be able to monitor tube output performance. Procedurelly; the management system requires work and the benefits to the workflow would need to be demonstrated.
机译:目前正在从英国西北部的医院放射学信息系统中收集数据,以用于临床审核和患者剂量审核。根据英国的指导,这些数据还能用于满足质量保证(qa)要求吗?从2008年到2009年;来自英格兰西北部的8家医院提交了731653条记录。用于自动曝光控制物理和工程学院的医学研究报告(ipem)的报告91建议,可以使用合适的体模来监视每秒毫安的可重复性和可再现性;在70-81千瓦时分析腹部ap和胸部pa检查以找到与这些记录一起使用的最常见的千伏,然后用于绘制随时间变化的平均每月每秒毫安。 Ipem报告91还建议使用一系列常用的临床设置来检查输出的可重复性和可重复性。对于每个管;绘制了两个最常见的暴露因子组随时间变化的剂量面积乘积值。结果表明,可以对AEC系统进行性能检查。然而,需要更多的工作来监控电子管输出性能。程序地;管理系统需要工作,并且需要证明工作流程的好处。

著录项

  • 来源
    《Radiation Protection Dosimetry》 |2011年第2期|p.215-219|共5页
  • 作者单位

    Intergrated Radiological Services Limited, Liverpool, UK;

    Intergrated Radiological Services Limited, Liverpool, UK;

    Intergrated Radiological Services Limited, Liverpool, UK;

    Intergrated Radiological Services Limited, Liverpool, UK;

    Intergrated Radiological Services Limited, Liverpool, UK;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号