首页> 外文期刊>Radiation Protection Dosimetry >DS86 AND DS02 ORGAN DOSE CALCULATIONS
【24h】

DS86 AND DS02 ORGAN DOSE CALCULATIONS

机译:DS86和DS02器官剂量计算

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

A brief review of the techniques used to calculate organ doses for the atomic-bomb survivors at Hiroshima and Nagasaki is provided using the original dosimetry system 1986 (DS86) and revised dosimetry system 2002 (DS02). The DS02 study was undertaken to address a serious discrepancy between calculated and measured values for neutron activation at Hiroshima that had caused a lack of confidence in the previous dosimetry, designated as DS86. Some potential improvements to the organ dose calculations that were not considered during the DS02 study due to time and funding limitations are recommended in this paper.
机译:使用原始的剂量学系统1986(DS86)和修订的剂量学系统2002(DS02),简要介绍了用于计算广岛和长崎原子弹幸存者器官剂量的技术。进行DS02研究是为了解决广岛中子活化的计算值与测量值之间的严重差异,该差异导致对先前称为DS86的剂量测定法缺乏信心。本文建议由于时间和资金限制而在DS02研究期间未考虑的器官剂量计算方面的一些潜在改进。

著录项

  • 来源
    《Radiation Protection Dosimetry》 |2012年第1期|p.15-20|共6页
  • 作者

    George D. Kerr;

  • 作者单位

    Department of Statistics, Radiation Effects Research Foundation, 5-2 Hijiyama Park, Minami-ku, Hiroshima 732-0815, Japan and Kerr Consulting, 1417 Paxton Drive, Knoxville, TN 37918-8012, USA;