首页> 外文期刊>Radiation Protection Dosimetry >EFFICIENCY AS A FUNCTION OF MEQ-CWT FOR LARGE AREA GERMANIUM DETECTORS USING LLNL PHANTOM
【24h】

EFFICIENCY AS A FUNCTION OF MEQ-CWT FOR LARGE AREA GERMANIUM DETECTORS USING LLNL PHANTOM

机译:使用LLNL幻像对作为大面积锗检测剂的MEQ-CWT的功效

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The lung counting system at Kalpakkam, India, used for the estimation of transuranics deposited in the lungs of occupational workers, consists of an array of three large area germanium detectors fixed in a single assembly. The efficiency calibration for low energy photons was carried out using ~(241)Am and ~(232)Th lung sets of Lawrence Livermore National Laboratory phantom. The muscle equivalent chest wall thickness (MEQ-CWT) was derived for the three energies 59.5, 75.95 (average energy of ~(232)Th) and 238.9 keV for the series of overlay plates made of different adipose mass ratios. Efficiency as a function of MEQ-CWT was calculated for individual detectors for the three energies. Variation of MEQ-CWT from 16 to 40 mm resulted in an efficiency variation of around 40 % for all the three energies. The array efficiency for different MEQ-CWT ranged from 1.4×10~(-3) to 3.2× 10~(-3), 1.5×10~(-3) to 3.3×10~(-3) and 1.1 × 10~(-3) to 2.3×10~(-3) for 59.5, 75.95 and 238.9 keV, respectively. In the energy response, efficiency was observed to be maximum for 75.95 keV compared with 59.5 and 238.9 keV.
机译:印度卡尔帕卡姆市的肺计数系统用于估算沉积在职业工人肺中的超铀元素,该系统由固定在单个组件中的三个大面积锗探测器组成。低能量光子的效率校准是使用Lawrence Livermore国家实验室幻象的〜(241)Am和〜(232)Th肺集进行的。对于由不同脂肪质量比制成的一系列覆盖板,这三种能量分别为59.5、75.95(〜(232)Th的平均能量)和238.9keV,得出了肌肉当量的胸壁厚度(MEQ-CWT)。计算了三种能量的单个探测器的效率与MEQ-CWT的关系。 MEQ-CWT从16毫米变化到40毫米导致所有三种能量的效率变化约40%。不同MEQ-CWT的阵列效率范围为1.4×10〜(-3)至3.2×10〜(-3),1.5×10〜(-3)至3.3×10〜(-3)和1.1×10〜分别为59.5、75.95和238.9 keV的(-3)至2.3×10〜(-3)。在能量响应中,观察到效率最高为75.95 keV,而效率为59.5和238.9 keV。

著录项

  • 来源
    《Radiation Protection Dosimetry》 |2012年第1期|p.121-125|共5页
  • 作者单位

    Environmental Survey Laboratory, Health Physics Division, Bhabha Atomic Research Centre, Kalpakkam 603102, India;

    Environmental Survey Laboratory, Health Physics Division, Bhabha Atomic Research Centre, Kalpakkam 603102, India;

    Environmental Survey Laboratory, Health Physics Division, Bhabha Atomic Research Centre, Kalpakkam 603102, India;

    Environmental Studies Section, Health Physics Division, Bhabha Atomic Research Centre, Mumbai 400085, India;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号