This paper describes modelling, application and validation of a filtration technique for a linear slot-scanning digital X-ray system to reduce radiation dose to paediatric patients while preserving diagnostic image quality. A dose prediction model was implemented, which calculates patient entrance doses using variable input parameters. Effective dose is calculated using a Monte Carlo simulation. An added filter of 1.8-mm aluminium was predicted to lower the radiation dose significantly. An objective image quality study was conducted using detective quantum efficiency (DQE). The PTW Normi 4FLU test phantom was used for quantitative assessment, showing that image contrast and spatial resolution were maintained with the proposed filter. A paediatric cadaver full-body imaging trial assessed the diagnostic quality of the images and measured the dose reduction using a 1.8-mm aluminium filter. Assessment by radiologists indicated that diagnostic quality was maintained with the added filtration, despite a reduction in DQE. A new filtration technique for full-body paediatric scanning on the Lodox Statscan has been validated, reducing entrance dose for paediatric patients by 36 % on average and effective dose by 27 % on average, while maintaining image quality.
机译:本文介绍了线性缝隙扫描数字X射线系统过滤技术的建模,应用和验证,以减少对儿科患者的辐射剂量,同时保留诊断图像的质量。实施了剂量预测模型,该模型使用可变的输入参数来计算患者的入院剂量。使用蒙特卡洛模拟计算有效剂量。预计增加一个1.8毫米铝过滤器会大大降低辐射剂量。使用探测量子效率(DQE)进行了客观的图像质量研究。使用PTW Normi 4FLU测试体模进行定量评估,结果表明所提出的滤镜可保持图像对比度和空间分辨率。儿科尸体全身成像试验评估了图像的诊断质量,并使用1.8毫米铝过滤器测量了剂量减少。放射科医生的评估表明,尽管DQE有所降低,但通过增加过滤可以保持诊断质量。 Lodox Statscan上的一种用于全身儿科扫描的新过滤技术已经过验证,可以在保持图像质量的同时,将儿科患者的入院剂量平均减少36%,将有效剂量平均减少27%。

著录项

  • 来源
    《Radiation Protection Dosimetry》 |2015年第4期|552-561|共10页
  • 作者单位

    MRC/UCT Medical Imaging Research Unit and Biomedical Engineering Programme, University of Cape Town, Cape Town, South Africa;

    MRC/UCT Medical Imaging Research Unit and Biomedical Engineering Programme, University of Cape Town, Cape Town, South Africa;

    MRC/UCT Medical Imaging Research Unit and Biomedical Engineering Programme, University of Cape Town, Cape Town, South Africa,University of Oxford, Oxford, UK;

    Groote Schuur Hospital, Observatory, Cape Town, South Africa;

    Groote Schuur Hospital, Observatory, Cape Town, South Africa;

    Red Cross War Memorial Children's Hospital, Mowbray, Cape Town, South Africa;

    Department of Medical Physics, University of Cape Town, Cape Town, South Africa;

    MRC/UCT Medical Imaging Research Unit and Biomedical Engineering Programme, University of Cape Town, Cape Town, South Africa,Lodox Systems, Johannesburg, South Africa;

    MRC/UCT Medical Imaging Research Unit and Biomedical Engineering Programme, University of Cape Town, Cape Town, South Africa;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号