The physical data regarding bremsstrahlung and neutrons produced in a steel shield by high-energy electron beams from a medical linear accelerator were investigated. These data are required to allow the accurate prediction of shielding performance for high-energy electron beams and in the design of radiotherapy facilities. A Monte Carlo code was used to develop Monte Carlo beam models for clinical electron beams and to directly simulate bremsstrahlung and secondary neutron production in a steel shield. The effective dose and dose equivalent of bremsstrahlung X rays and secondary neutrons outside a vault were determined using a realistic radiation source. The accuracy of Monte Carlo simulations was validated experimentally by comparing the measured and calculated physical quantities. In validating the Monte Carlo simulation, the measured and calculated values showed reasonable agreement, indicating that bremsstrahlung and photoneutron production and transport were simulated accurately. The bremsstrahlung X-ray dose was the main component of the total dose outside a vault. The secondary neutron dose was 1-20 % of the bremsstrahlung X-ray dose, but the neutron dose was also at a non-negligible level. The calculated neutron dose outside the vault differed from the McGinley's reported data. These results indicate that McGinley's method overestimates the neutron dose beyond the steel shield. The physical data used here will be useful in the accurate estimation of bremsstrahlung X-ray and neutron doses for high-energy electron beams.
机译:研究了由医用线性加速器产生的高能电子束在钢质屏蔽层中产生的致辐射和中子的物理数据。需要这些数据才能准确预测高能电子束的屏蔽性能以及放射治疗设备的设计。使用蒙特卡洛代码开发用于临床电子束的蒙特卡洛束模型,并直接模拟钢盾中的致辐射和次级中子产生。使用现实的辐射源确定外X射线和穹顶外的次级中子的有效剂量和等效剂量。通过比较测量和计算的物理量,通过实验验证了蒙特卡洛模拟的准确性。在验证蒙特卡洛模拟时,测量值和计算值显示出合理的一致性,表明致辐射和光中子的产生和传输得到了准确的模拟。致辐射X射线剂量是穹顶外总剂量的主要成分。次级中子剂量是the致辐射X射线剂量的1-20%,但中子剂量也处于不可忽略的水平。穹顶外计算出的中子剂量与麦金利的报告数据不同。这些结果表明,McGinley的方法高估了钢屏蔽层以外的中子剂量。此处使用的物理数据将有助于准确估算高能电子束的致辐射X射线和中子剂量。

著录项

  • 来源
    《Radiation Protection Dosimetry》 |2015年第2期|148-159|共12页
  • 作者单位

    Department of Radiation Oncology, Tokai University School of Medicine, Isehara, Kanagawa 259-1193, Japan;

    Graduate School of Human Health Sciences, Tokyo Metropolitan University, Arakawa-ku, Tokyo 116-8551, Japan;

    Graduate School of Human Health Sciences, Tokyo Metropolitan University, Arakawa-ku, Tokyo 116-8551, Japan;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号